GO-5101M-PMCL-1 | GO-5101C-PMCL-1 | User Manual (Ver. 1.0)
Main Functions
- 65 -
Internal Camera Blocks
To Use the Counter Function
Configure the settings as follows. Three counters can be configured (Counter 0 to 2).
Item
Setting Value / Selectable Range
Description
Counter 0 ~ 2
Counter 0 ~ 2
Select the counter.
- Counter 0 ~ 2
Event Source
Off, Frame Trigger, Frame Start, Exposure
Start, Frame Transfer End
Select the counter event signal for which
to read the count value.
- Counter 0 ~ 2
Event Activation Rising Edge (fixed) or Falling
Edge
Specify the timing at which to count.
Note:
The four counter event signals are always counted up internally on the camera.