When Exposure Mode is Trigger Width
Example: When Trigger Source is set to Line 7 - CC1
1. Trigger Overlap: Off
Tap
Geometry
CL Pixel
Clock
(MHz)
Period from Trigger
start edge to Exposure
start A (usec)
Period from
Exposure end to
FVAL start B (usec)
Period FVAL end
to next trigger
start C (usec)
Max
Exposure
msec
Min
Exposure
usec
1X2 - 1Y
37.125
101
851
851 -
Expo(Current)
+ Expo(Next)
69.116
47.7
1X2 - 1Y
74.25
51
435
934 -
Expo(Current)
+ Expo(Next)
34.558
30.7
1X2 - 1Y
84.85
45
384
939 -
Expo(Current)
+ Expo(Next)
30.336
28.7
1X3 - 1Y
37.125
68
573
906 -
Expo(Current)
+ Expo(Next)
46.189
36.7
1X3 - 1Y
74.25
42
354
942 -
Expo(Current)
+ Expo(Next)
27.847
27.7
1X4 - 1Y
37.125
51
436
937
- Expo(Current)
+ Expo(Next)
34.669
30.7
1X4 - 1Y
74.25
42
314
952
- Expo(Current)
+ Expo(Next)
27.847
27.7