![JAI GO-5101C-PGE User Manual Download Page 29](http://html.mh-extra.com/html/jai/go-5101c-pge/go-5101c-pge_user-manual_631473029.webp)
— 29 —
GO-5101M-PGE / GO-5101C-PGE
Shortest Repetition Period for Triggers
The reciprocal of the maximum frame rate is the time required to output one frame. The shortest
repetition periods for triggers cannot be lower than that value.
Scanning range
Shortest period
8-bit (at 14 μs)
10-bit packed (at 27 μs)
10-bit (at 27 μs)
Full
44.05 ms
66.08 ms
88.10 ms
ROI 2/3 (Height = 1370)
19.56 ms
37.14 ms
39.12 ms
ROI 1/2 (Height = 1028)
14.32 ms
28.13 ms
28.13 ms
ROI 1/4 (Height = 514)
7.43 ms
14.59 ms
14.59 ms
ROI 1/8 (Height = 257)
3.98 ms
7.82 ms
7.82 ms
Binning Vertical 2*
22.03 ms
33.04 ms
44.05 ms
The values in parentheses indicate exposure time.
* GO-5101M-PGE only
The shortest periods of trigger in the table above are values for when the trigger overlap is set to
“Readout.” When the trigger overlap is set to “Off,” the exposure time will be added to the periods.
■
When [Exposure Mode] is [Timed]
Example: When [Trigger Source] is set to [Line 5 - Optical In 1] and [OptIn Filter Selector] is set to
[10 µs]
•
Trigger overlap: Off
Next trigger disabled
Next trigger
input enabled
(*)
Readout
Sensor
Exposure
Trigger
Exposure
Active
t2
t3
t1
t1
t2
t
3
8 bit
10
μ
s
(Minimum)
40
μ
s
28
ms
10 bit packed
79
μ
s
55
ms
10 bit
(Minimum)
* If the exposure time is longer than (input trigger cycle - t3), the next trigger input
can not be accepted.