— 18 —
GO-5100M-USB / GO-5100C-USB
1
Set [Exposure Mode] to [Trigger Width] .
When you select [Trigger Width], [Trigger Mode] will automatically be set to [On].
2
Set [Trigger Selector] to [Frame Start].
([Frame Start] is the default setting.)
3
If necessary, change the [Trigger Source] and [Trigger Activation] settings.
Other controls
In addition to exposure time, the following can also be controlled by external triggers. Select these
control operations in [Trigger Selector].
[Trigger Selector] setting
Description
Acquisition Start
Start image acquisition.
Acquisition End
Stop image acquisition.
Acquisition Transfer Start
Output acquired images at a specified timing. (Up to 8
frames for 8-bit, and up to 4 frames for 10-/12-bit.)
Control Without External Triggers
When Controlling the Exposure Time Using Specified Exposure Times
Configure the settings as follows.
Item
Setting value / selectable range
Trigger Selector (trigger operation)
Frame Start
Trigger Mode
Off
Exposure Mode
Timed (control via exposure time)
Exposure Time
8 bit: 7 to 13427 (µs)
10/12 bit: 8 to 26921 (µs)
Exposure Auto
Off, Continuous
1
Set [Exposure Mode] to [Timed].
([Timed] is the default setting.)
2
Specify the exposure time in [Exposure Time].
The setting value for the exposure time can only be changed when [Exposure Auto] is set to [Off].
If [Exposure Auto] is set to [Continuous], temporarily set it to [Off] before changing the exposure
time.
3
Set [Trigger Mode] to [Off].
4
If necessary, change the [Exposure Auto] setting.