GO-5000M-USB / GO-5000C-USB
- 42 -
Note 1: The trigger is input through 6P optical input. Accordingly, the timing will be changed if
the optical filter is set to the other figures.
Note 2: Other timings are internal operating timing of the camera.
Fig.24 Pulse width
8.7. RCT mode
8.7.1 RCT mode together with ALC function
RCT mode can use ALC control to ensure that the proper exposure is set when the trigger pulse is
input. In the following drawing, the steps to achieve this combination are explained.
①
The exposure control is the same as in continuous mode.
②
When the trigger signal is input, the charge that has already been accumulated during the
current exposure period is read out very quickly and a new exposure period starts. The
exposure continues as in continuous mode.
③
All video level data from every exposure is transferred to ALC control.
④
The video output sent to the GigE interface is only the signal after the trigger is input.
Trigger
CMOS
Exposure
FVAL
Exposure
Active
Exposure Period
t3
t1
t2
t4
t1
t2
t3
t4
10 μs (Min)
36 μs
5L
~
6L
32 μs