Pulse Generator
Related Setting Items:
Tips for using the Pulse Generator
This camera has a frequency divider using the sensor clock as the basic clock and one pulse
generator. In the Pulse Generator, various Clear settings are connected to GPIO. The following shows
the Pulse Generator default settings.
The sensor pixel clock is 36 MHz for 8-bit, 28.8MHZ for 10-bit and 24 MHZ for 12-bit.
Pulse Generator Default Settings
Display Name
Value
Clock Pre-scaler
107
Pulse Generator
Scaler
Pulse Generator
Length Start Point
End
Point
Repeat Count
Clear
Source
Clear
Activation
Clear Sync
Mode
Pulse Generator 0
30000
0
15000
0
Low
Free Run
Async Mode
Note:
When Pulse Generator Repeat Count is set to “0”, the camera is operating in free-running
mode.
Clock Pre-scaler
Clock pre-scaler (Divide Value) can set the dividing value of the frequency divider (12-bit length) and
the sensor clock is used for this. This camera's Pixel Clock is 48.5714MHz.