background image

- 3 -

CV-M532

1. General

The model CV-M532 is a new remote micro-head camera system featuring virtually identical
performance and function of the popular CV-M50 standard machine vision camera.

Precisely installed CCD imager (1/3") and miniature size (ø12mm) allows access to very contained
spaces. The remote micro-head weights only 5g (0.031lbs) .
The new 1/3" Hyper HAD imager employed in the CV-M532  provides superior sensitivity and higher
dynamic range with improved smear level.

High speed shutter and asynchronous random trigger functions allow a superb image quality in
machine vision and image processing applications such as dynamic motion image capturing, on-line
inspection, gauging, printing and graphics.

Model

Cable length

CV-M532

2.0m (6.45 feet)

(Cable is directly mounted on camera head)

Important Notice!

CV-M532 has inter-changeability between camera head and CCU within the same model.

2. Standard Composition

1) Camera head

x1 (incl. camera cable)

2) Camera control unit

x1

3) Operation manual

x1

Options

 (Following optional accessories are available upon request.)

1) 12pin Multi Connector (HR10A-10P-12S)
2) 6pin Multi Connector (HR10A-7P-6S)
3) MP-40 Tripod mount adaptor
4) MP-35 Micro-head fixing mount adaptor
5) MP-25 C-mount adaptor
6) OP-105 Special lens (7.5mm, F1.6)

Summary of Contents for CV-M532

Page 1: ...Operation Manual Remote Head Monochrome CCD Camera Rev E CV M532 ...

Page 2: ...RATION OF CONFORMITY AS DEFINED BY THE COUNCIL DIRECTIVE 89 336 EEC EMC ELECTROMAGNETIC COMPATIBILITY WE HEREWITH DECLARE THAT THIS PRODUCT COMPLIES WITH THE FOLLOWING PROVISIONS APPLYING TO IT EN 50081 1 EN 50082 1 ...

Page 3: ...posure Mode 13 7 Mode Setting 15 7 1 1 SW1 Switch on the Rear Panel 15 7 1 2 Table for SW 1 Setting 15 7 1 3 Table for Shutter Time 15 7 1 4 Ext Trigger Shutter Mode 16 7 1 5 Trigger Select 16 7 1 6 CD Accumulation 16 7 1 7 Scanning System 16 7 1 8 Gamma Correction 16 7 1 9 Gain Control 16 7 2 SW2 on PK8057 Board 16 7 3 Jumper Settings 17 7 3 1 Jumper on PK8054 Board 17 7 3 2 Jumper on PK8057 Boar...

Page 4: ...ions allow a superb image quality in machine vision and image processing applications such as dynamic motion image capturing on line inspection gauging printing and graphics Model Cable length CV M532 2 0m 6 45 feet Cable is directly mounted on camera head Important Notice CV M532 has inter changeability between camera head and CCU within the same model 2 Standard Composition 1 Camera head x1 incl...

Page 5: ...oved low smear and higher dynamic range Edge pre select and pulse width external trigger modes High speed and random trigger shutter up to 1 10 000 sec Long time exposure mode 1 30 sec EIA WEN and EEN output pixel clock output user option to support further advanced image capturing Internal external HD VD synchronization Easy access for mode setting of shutter and other function from rear panel Le...

Page 6: ...lti connector Output WEN EEN signal and input external trigger pulse etc 5 GAIN To adjust gain level 6 12P Multi connector Input DC 12V power and input output of HD VD signal etc 7 Screw holes for Tripod mount plate To fix tripod mount plate optional on camera 8 CCD sensor 1 3 Hyper HAD Interline transfer CCD sensor 9 Focus adjustment ring To adjust lens focus 10 Camera head 11 connector To connec...

Page 7: ...in Multi connector DC IN SYNC Type HR10A 10R 12PB Hirose male Seen from rear Notes 1 Signals on pin no 6 7 and 9 can be changed by jumper setting See 7 3 Jumper Settings for more information 2 In Edge Pre select and Pulse Width Control mode do not input ext VD signal Pin no Signal Remarks 1 NC 2 EEN output Note 3 GND 4 NC 5 Ext Trig input Note 6 WEN output Note 5 2 6 pin Multi connector TRIGGER Ty...

Page 8: ...mode Exposure control by the interval of the ext VD signal The trigger input is AC coupled so there is a maximum pulse width for the trigger pulse about 60 msec The signal level must be 4 0V p p 2 0V on the input with the 75 Ohm termination ON To change to non terminated input see instructions in 7 Mode Setting The following describes the details of each trigger mode 6 3 1 Edge Pre select Mode The...

Page 9: ...gnal To avoid this 1H delay and jitter the falling edge of the trigger pulse should be synchronized with the HD pulse as shown below It can be the ext HD input or the Internal HD output 3 The ext trigger input is 75 Ohm terminated as factory setting R127 short and SW2 2 ON The voltage level of the ext trigger has to be 4 0 Vp p 2 0 V The duration should be more than 1 H negative going 64 µsec and ...

Page 10: ...ndicates the time period of the effective video signal output and is useful for the timing and interfacing of external devices such as frame grabbers The WEN pulse is output from pin 6 of the 6 pin multi connector The signal level is 4 0 Vp p from a 75 Ohm source The video must be read out before a new trigger can be applied The interval between trigger pulses must be longer than the time for 1 fi...

Page 11: ... 75 Ohm terminated as factory setting R127 short and SW2 2 on The voltage level of the ext trigger has to be 4 0 Vp p 2 0 V The duration should be more than 1 H negative going 64 µsec and 60 msec The input is AC coupled 4 If the ext trigger input and ext HD input are from a source with TTL level set SW2 1 and SW2 2 OFF for non terminated SW2 1 for HD signal SW2 2 for ext trigger pulse See 7 2 SW2 ...

Page 12: ...ed as follow Both modes have 2 fields output in an interlaced frame With frame accumulation the contents in the ODD and EVEN sync fields will come from sensing field 1 and 2 on the CCD sensor With field accumulation both ODD and EVEN sync field will contain the signal from sensing field 1 and 2 added together Non interlaced with field accumulation needs only 1 trigger pulse for each field To use t...

Page 13: ...ger has to be TTL level 2 0 to 5 0 V It cannot be 75 Ohm terminated The duration should be more than 1 H negative going 64 µsec and 1 msec The input is AC coupled 4 If the ext VD input and ext HD input are from a source with TTL level set SW2 1 and SW2 2 on PK8057 board OFF for non terminated SW2 1 for ext HD signal SW2 2 for ext VD signal See 7 2 SW2 on PK8057 Board 5 Each scanning mode requires ...

Page 14: ...from 1 V a single field to However the dark current signal will increase by longer time so 2 seconds are not recommended at normal ambient temperature To use this mode Set SW1 1 2 and 3 to OFF SW1 4 to OFF for normal shutter SW1 5 to ON for frame accumulation or OFF for field accumulation SW1 6 to OFF for 2 1 interlaced or ON for non interlaced Jumper JP6 on PK8057 to CLOSE Input Ext VD pulses wit...

Page 15: ... may occur 3 Ext HD signal 4 0 Vp p 2 0V at 75 Ohm terminated has to be input continuously The falling edge of Int HD signal and Ext VD signal are phase synchronized 4 Timing of ext VD signal in each accumulation mode has to be set as described before a 2 1 Interlaced mode Field accumulation mode b 2 1 Interlaced mode Frame accumulation mode c Non interlaced mode Field accumulation mode ...

Page 16: ...on interlaced 7 Gamma correction Gamma 1 0 Gamma 0 45 8 Gain Manual gain AGC on 7 Mode Setting Caution on Mode Setting Before making any mode or jumper setting turn the power OFF 7 1 1 SW1 Switch on the Rear Panel Factory settings for SW1 are with all 8 switches in OFF position 7 1 2 Table for SW 1 Setting 7 1 3 Table for Shutter Time Caution on Shutter The image can flicker when the illumination ...

Page 17: ...ng system OFF is 2 1 interlaced It will follow the EIA or CCIR standard for interlaced scanning ON is non interlaced In EIA the non interlaced output is continuous ODD field In CCIR the non interlaced output is continuous EVEN field If the camera is ext HD VD synchronized with a non interlaced sync SW1 6 be in ON position 7 1 8 Gamma Correction SW1 7 will select the gamma correction OFF is gamma 1...

Page 18: ...tput Factory set input JP4 Open Short Open Open Open Open JP5 Short Short Short Short Short Short JP6 Open Open Open Open Open Short Long time integration JP7 Short Short Short Short Open Short JP8 Open Open Open Open Short Open JP9 Open Open Open Open Short Open JP10 Open Open Open Open Short Open JP11 Open Pixel clock out Factory set OPEN JP12 Short Short Short Open Short Short Pulse width SW2 1...

Page 19: ... a 0 Ohm resistor or by a soldering between the 2 points To remove the solder tin from a jumper position use a special tin remover such as de soldering wick 7 4 1 Board PK8054 Side B 7 4 2 Board PK8057 Side A R127 JP10 JP2 JP1 SW2 JP6 JP7 JP9 1 JP 2 JP4 JP3 JP5 JP8 JP11 ...

Page 20: ...ctor This adjustment should only be done in a setup with a standard TV test chart and controlled illumination VR3 To adjust the gain level of AGC Factory setting 700 mVp p 30 mV VR4 To adjust the white level Factory setting 800 mVp p 20 mV VR5 To adjust the black level Factory setting 20 mVp p 5 mV CAUTION Do not touch these potentiometers unless you are familiar with camera adjustments Location o...

Page 21: ... 20 CV M532 9 External Appearance Unit mm inches 9 1 CCU 4 9 0 19 2 0 08 Cable 4 6 0 18 50 1 97 7 3 in glass 0 2 7 05 in air 0 2 12 0 47 M10 5x0 5 HR10A 10TP 12P 50 1 97 6 0 24 26 1 02 9 2 HEAD ...

Page 22: ...e enable 4V 75 Ohm EEN output exposure enable 4V 75 Ohm Pixel clock output optional 4V 75 Ohm sine Normal shutter Off 1 100 1 250 1 500 1 1000 1 2000 1 4500 1 10 000 sec Edge pre select shutter 1 60 1 125 1 250 1 500 1 1000 1 2000 1 4500 1 10 000 sec Pulse width controlled shutter 1 H 64 µsec to 60 msec Start stop trigger shutter 1 77 sec to 1 10 000 sec Long time exposure 1 field to Duration betw...

Page 23: ...wing effects may be observed on the video monitor screen They do not indicate any fault of the CCD camera but do associate with typical CCD characteristics V V V V V Smear Smear Smear Smear Smear Due to an excessive bright object such as electric lighting sun or strong reflection vertical smear may be visible on the video monitor screen This phenomenon is related to the characteristics of the Inte...

Page 24: ...er 1 18 2 Hakusan Midori ku Yokohama Kanagawa 226 0006 Japan Phone 81 45 933 5400 Fax 81 45 931 6142 www jai corp co jp JAI A S Denmark Produktionsvej 1 2600 Glostrup Copenhagen Denmark Phone 45 4457 8888 Fax 45 4491 8880 www jai com 2700 11107E E1 0101 12 User s Record Camera type CV M532 Scanning system EIA Revision Revision E Serial No Users Mode Settings Users Modifications ...