CV-M4
+
/M4
+
CL, CV-M7
+
/M7
+
CL
- 24 -
7.5. CV-M4
+
command list
Command Name
Format
Parameter
Remarks
A – General settings and useful commands
EB
Echo Back
EB=
[
Param.
]
<CR><LF> 0=Echo off
1=Echo on
Off at power up
ST
Camera Status request ST?<CR><LF>
Actual setting
HP
Online Help request HP?<CR><LF>
Command list
VN
Firmware version
VN?<CR><LF>
3 letter version
B – Timing and shutter related commands
SC
Scanning format
SC=
[
Param.
]
<CR><LF> 0=full frame
2=1/4 partial
1=1/2 partial
3=1/8 partial
*1)
TR
Trigger mode
TR=
[
Param.
]
<CR><LF> 0=normal
2=Pulse width
1=Edge
3=Frame delay
HC
H synchronous accum
HC=
[
Param.
]
<CR><LF> 0=H synchr
1= H a-synchr
SM
Shutter mode
SM=
[
Param.
]
<CR><LF> 0=Normal 1=Programmab.
SH
Shutter speed
SH=
[
Param.
]
<CR><LF> 0=Off (1/24)
2=1/100
4=1/400
6=1/1500
8=1/5500
1=1/50
3=1/200
5=1/800
7=1/3000
9=1/10,000
All10 steps are
valid in normal
trigger mode.
PE
Programmable expos.
PE=
[
Param.
]
<CR><LF>
0=2.5 H,
1=3.5H
1055=1057.5 H
H= 39.3
µ
sec
Bin. H= 43.3
µ
sec.
BI
Binning
BI=
[
Param.
]
<CR><LF>
0=off 1=vertical
*1). Only for SC=0.
M4
+
and M4
+
CL
SL
Smearless
SL=
[
Param.
]
<CR><LF>
0=Off 1=ON
TR=1, 2 or 3
RC
Reset Continuous Trig
RC=
[
Param.
]
<CR><LF> 0=Off 1=ON
Only for TR=1
C – Signals and polarity
SO
Sync on video
SO=
[
Param.
]
<CR><LF> 0=no sync on v. 1=sync on v.
Pin #4 on 12 pin
ML
MuLtiple shutter
ML=
[
Param.
]
<CR><LF> 0=OFF 1=On
Multi Trig input
TR=3
SE
Sync/EEN
SE=
[
Param.
]
<CR><LF>
0= Sync out
1=EEN out
Pin #9 on 12 pin
FP
FEN/LEN/EEN polarity
FP=
[
Param.
]
<CR><LF> 0= active low
1= active high
TP
Trigger polarity
TP=
[
Param.
]
<CR><LF> 0= active low
1= active high
*2)
TI
Trigger Input
TI=
[
Param.
]
<CR><LF>
0= Hirose 12p
1= LVDS (CL)
D – Gain and analogue signals setting
GA
Manual gain Level
GA=
[
Param.
]
<CR><LF> 0=low 510=high
Range 0 to 510
RP
Rear Potentiometer
RP=
[
Param.
]
<CR><LF> 0=manual gain
1=rear potm.
SU
Setup Level
SU=
[
Param.
]
<CR><LF> 0=low 255=high
Range 0 to 255
E – Saving and loading data in EEPROM
LD
Load settings from
camera EEPROM
LD=
[
Param.
]
<CR><LF> 0=Factory data
2=User 2 area
1=User 1 area
3=User 3 area
Latest used data
area becomes
default at next
power up
SA
Save settings to
camera EEPROM
SA=
[
Param.
]
<CR><LF> 1=User 1 area
3=User 3 area
2=User 2 area
Parameter = 0 is
not allowed
EA
EEPROM area request
EA?<CR><LF>
0=Factory data
3=User 3 area
1=User 1 area
3=User 3 area
Return the used
data from area
*3)
*1)
Binning can also be selected by the internal switch SW301.6. Binning has priority over partial scanning. If partial scanning
is active when a binning mode is activated, binning will take over and the scanning will be full. The line frequency will be
lower in V binning modes (H= 43.3
µ
sec.).
*2)
If positive logic is used (TP=1), the first trigger pulse after power up will be ignored.
*3)
Data from the latest used data area is loaded as default on power up.
!!
Do not try to use commands not shown in the list
.