CM-030GE/CM-030GE-RA / CB-030GE/CB-030GE-RA
- 47 -
In the case of Sequential EPS, (Trigger source is Software)
For each sequence,
The following table shows the minimum trigger interval in synchronous accumulation mode. In
case of a-synchronous accumulation mode, the exposure time should be added to figures in
this table.
Full Scan
2/3Partial
1/2 Partial
1/4 Partial
1/8 Partial
1/2 V Binning
514 L
364 L
294 L
185 L
132 L
261 L
The conditions for this table are that the shutter speed should be set the same for all
sequences.
If the shutter speed is different, the difference of exposure time should be added. It is
recommended to set the exposure time in the order from the shortest to the longest one.
The minimum trigger interval is > Exposure time (expressed in L(Line)) + FVAL on Normal
scan ( 511L) + 1L )
Do not input the trigger just after the sequence is reset. It requires at least 500ms delay.
In sequential mode, the exposure should be adjusted so that the LVAL a-sync mode can
always be functioned.