CM-040MCL /-RA / CB-040MCL /-RA
27
Command
Name
Format
Parameter
Remarks
D -Image Format
1
Bit Allocation
BA
=[Param.]<CR><LF>
BA?<CR><LF>
0=10bit, 1=8bit
2
Scan Format
SC
=[Param.]<CR><LF>
SC? <CR><LF>
0=Full Frame, 1=2/3 Partial
2=1/2 Partial, 3=1/4 Partial
4=1/8 Partial
5
V-Binning
VB
=[Param.]<CR><LF>
VB?<CR><LF>
0=OFF
1=On
Only
CM-040MCL
E - Gain, Black and signal settings
1
Gain Level
GA
=[Param.]<CR><LF>
GA?<CR><LF>
-84 to 336
2
Black Level
BL
=[Param.]<CR><LF>
BL?<CR><LF>
0to 1023
F - Saving and loading data in EEPROM
1
Load Setttings
(from Camera
EEPROM)
LD
=[Param.]<CR><LF>
0=Factory area
1=User 1 area
2=User 2 area
3=User 3 area
Latest used
DATA AREA
becomes
default at
next power
up.
2
Save Settings
(to Camera
EEPROM)
SA
=[Param.]<CR><LF>
1=User 1 area
2=User 2 area
3=User 3 area
Note : 0 is not allowed
3
EEPROM
Current Area No
Request.
EA
?<CR><LF>
0=Factory area
1=User 1 area
2=User 2 area
3=User 3 area
The camera
returns the
latest used
DATA AREA.
NOTE: Do not try to use commands not shown in this list.