CM-030GE/CM-030GE-RA / CB-030GE/CB-030GE-RA
- 19 -
Pulse Generator 0
100 Line
500 Line
1000 Line
output
Pulse Generator 0
100 Line
500 Line
1000 Line
output
6.5.3 Internal Trigger Generator
Create a trigger signal and trigger the camera
Feature
Value
c)Acquisition
and
Trigger controls
Trigger
selector
Trigger Mode
ON
Pulse Generators
Pulse
Generator
selector
Pulse Generator 0 Selector
Clock Choice
1
=
Pixel
Clock
(40MHz)
Counter Dividing Value
864(line rate)
Length Counter 0
1000 Clocks
Start point Counter 0
100 Clocks
Repeat Count 0
0
End point Counter 0
500 Clocks
Clear activation
Off
Trigger source
pulse generator 0
Fig.14. Pulse Generator 0 timing Example 2
LUT
(
Cross point switch)
12bit
Counte
Pulse Generator 2
(20bit Counter)
Pulse Generator 1
(20bit Counter)
Pulse Generator 0
(20bit Counter)
LUT
(
12bit
Pulse Generator 3
(20bit Counter)
LVAL IN
DVAL IN
FVAL IN
EEN IN
OPT IN 1
OPT IN 2
Soft Trigger 0
Soft Trigger 1
Soft Trigger 2
Soft Trigger 3
( Cross Point Switch )
Trigger 0
Trigger 1
OPT OUT 1
OPT OUT 2
Time Stamp Reset
Counter
25 MHz
Pixel Clock(40MHz)
Line Rate 46.296 KHz