- 20 -
Horizontal Timing
The horizontal timing is the same the full scanning.
H-Timing FULL FRAME READ OUT / PATIAL READ OUT
1LVAL 1924ck = 32us
1ck=
16. 66ns
LVAL
DATA OUT
OB
Valid data
OB
40ck
1228ck
1268ck
656ck
DVAL
1228ck
696ck
Fig. 17. Horizontal timing for partial scanning
6.3.5.
Vertical Binning
Vertical binning combines charge from two adjacent lines, reducing the vertical resolution to half
and at the same time increasing frame rate and sensitivity. By activating this function, the frame
rate is increased to 48.87 fps.
This function is available only for BM-500CL.
Important Note
Vertical Binning can not be used together with the Partial Scanning.
Horizontal Timing
H-Timing V binning
1LVAL 2524ck = 42.07us
1ck=16.66
ns
LVAL
DATA OUT
OB
Valid data
OB
40ck
1228ck
1268ck
1256ck
DVAL
1228ck
1296ck