BM-141GE / BB-141GE
15
The following shows JAI SDK Camera Control Tool for setting Pulse Generator.
5.5
Opto-isolated Inputs/Outputs
The control interface of the C3 GigE Vision camera series has opto-isolated inputs and outputs,
providing galvanic separation between the camera's inputs/outputs and peripheral equipment.
In addition to galvanic separation, the opto-isolated inputs and outputs can cope with a wide
range of voltages; the voltage range for inputs is +3.3V to +24V DC whereas outputs will
5V to +24V DC.
Fig.9. Photo coupler
5.5.1
Recommended External Input circuit diagram for customer
Fig.10. External Input Circuit
、
OPT IN 1 and 2