AP-1600T-PMCL | AP-3200T-PMCL | User Manual (Ver. 2.0)
Main Functions
- 44 -
ClConfiguration / PixelFormat
CameraLink Clock Frequency
ExposureMode
Option = RCT
AP-1600T-PMCL
AP-3200T-PMCL
Full/RGB8
37.125MHz
22
16
74.25 MHz
12
9
84.86 MHz
12
9
EightyBit/RGB8
37.125MHz
18
13
74.25 MHz
12
9
84.86 MHz
12
9
Trigger Control
Related Setting Items:
The camera allows the following controls to be performed via external trigger signals.
l
FrameStart: Start exposure in response to the external trigger signal input. Select this to perform
exposure control using external triggers.
1)
Notes:
l
The settings for exposure control and triggers are related to each other. Be sure to configure
the settings described in “
”.
l
1)
You can delay when exposure actually starts after a trigger is received by a specific
amount of time by configuring
TriggerDelay
.