8.4.1
Readjusting concentricity
Ü
Loosen the axial clamping screws.
Ü
Manually rotate the HF spindle by 360°.
Ä
Detect run-out errors.
Ü
Reset the concentricity of the HF spindle using the radial adjustment
screws.
Ü
Tighten the axial clamping screws crosswise.
Ä
Recommended torque: 8.7 Nm
Ü
Manually rotate the HF spindle by 360°.
Ä
Check concentricity.
Repeat the steps if required.
Note: Ensure functionality.
All contamination damages the collet, clamping nut, tool mount, etc. As a re-
sult, the function of the HF spindle is no longer guaranteed.
u
Clean the collet.
u
Clean the clamping nut.
u
Clean the thread of the shaft.
u
Clean the inner taper of the shaft.
Ü
Screw the collet and clamping nut onto the HF spindle.
Ü
Secure all connections for the HF spindle.
8.5
Diameter of media supply line
Ü
The nominal size of the media supply lines can be found in the following
table:
DN
Medium
D1
D2
2.8
Compressed air
2.8 mm
7
/
64
"
4 mm
5
/
32
"
4
Compressed air
4 mm
5
/
32
"
6 mm
15
/
64
"
6
Compressed air
6 mm
15
/
64
"
8 mm
5
/
16
"