4. INSTALLATION
01
Ensure the location facilitates good heat distribution for the room and that the wall and floor is flat and sound.
Care to be taken when attaching brackets to ensure they are both the correct way round.
05
CLICK!
CLICK!
H 200
H 350 - 500 - 650 - 950
03
Take the heating element and remove the protective covering
from the connection end only. The rest of the covering can be
removed later in the process. Leaving it on at this stage protects
the element from building and decoration debris.
Air Vent
Connection
04
Connection can be either on the left or right hand side, for either
option, make sure the 1/8th connection for the air vent is on the
top of the heating element.
• Minimum clearance from floor to underside of casing for STRADA equals ‘h’ dimension.
• The supplied fixings are suitable for solid wall construction only. For other wall structures alternative fixings must be used.
• If third and fourth brackets are supplied, these are to be fitted to the central plates of the heat exchanger. Fixing centres to
be marked at time of installation.
02
90
H
75
25
min. 100*
h
130
65
125
L
d
B
55
95
125
(T10/15/20)
255
(T06/11/16/21)
Type
B (mm) d (mm) h (mm)
06
85
40
100
10/11
118
53
100
15/16
168
78
120
20/21
218
103
150
H 200
NOTE:
Flow and return
connections can be either left
hand or right hand. This can be
decided at time of installation.
Dimensions shown are for right
hand connections. For left hand
connections, dimensions are
mirrored.