Place the supply and return pipes and the electricity cable. These
must stick out a minimum of 6 cm in the casing.
07
Min. 6cm
Place the protective block.
If screed is used the device needs to be completely insulated in
order to protect the device from voltage differences.
08
09
If the device is not mounted directly on the floor, the space under
the device must be filled.
Mark the drill holes. Drill the holes and place the plugs.
Fix the device to the floor with the height adjusters.
Use the correct plug for your floor type. !
06
05
Remove the protective block and the connecting pieces.