background image

ROUGH-IN DIMENSIONS

2-1/8" MIN.

REF. DIM.

2-3/4" D.

2-3/4" D.

2-7/8" MAX.

Handle Trim kits for 1/2" and 3/4"
Straight Wall Valves

Plumbers' Putty or Caulking

Adjustable Wrench

TOOLS REQUIRED

2-3/8" MIN.

REF. DIM.

3-1/8" MAX.

6

7

8

6

7

8

9

CAUTION

Turn off hot and cold water

supplies before beginning.

CAUTION

Turn off hot and cold water

supplies before beginning.

1

INSTALL CROSS HANDLE

Place BARREL SLEEVE (1) over VALVE STEM (2) and thread tight onto VALVE (3).

With VALVE in off position align and install CRYSTAL HANDLE (6) onto VALVE STEM (2)
and tighten HANDLE SCREW (7). Thread INDEX (8) into CRYSTAL HANDLE (6).

Apply sealant to groove on back side of ESCUTCHEON (4). Slide ESCUTCHEON (4) onto BARREL SLEEVE (1) flush
against finished wall to cover wall opening.

Thread BONNET NUT (5) onto BARREL SLEEVE (1) until it seats tight against the internal stop.

2

INSTALL LEVER HANDLE

Place BARREL SLEEVE (1) over VALVE STEM (2) and thread tight onto VALVE (3).

For Lever Handles:

 Install FRICTION WASHER (6) onto base of

LEVER HANDLE (7, 8). With VALVE in off position align LEVER
HANDLE (7, 8) as shown or as desired. Install LEVER
HANDLE (7, 8) onto VALVE STEM (2) and tighten
SET SCREW (9) with HEX WRENCH (5) supplied. 

Apply sealant to groove on back side of ESCUTCHEON (4). Slide ESCUTCHEON (4)
onto BARREL SLEEVE (1) flush against finished wall to cover wall opening.

1 0 9 5 9 2

1 0 9 5 9 2

Regular Screwdriver

1/2" NPT VALVE

3/4" NPT VALVE

SEALANT

SEALANT