RECOMMENDED TOOLS 

Teflon Tape

Phillips Screwdriver

Regular Screwdriver

1

ROUGHING-IN

Turn off water at main supply.

CAUTION

            When soldering, remove PLASTER GUARD, CARTRIDGES and CHECK

STOPS (IF PRESENT). When finished soldering, flush valve body, replace

cartridges, check stops (if present) and plaster guard to continue installation.

Use thread sealant or Teflon tape on threaded connections.

NOTE

If the valve is installed on a fiberglass or

other thin wall application, the PLASTER

GUARD 

(3)

 can be used as a support.

Connect hot and cold water supplies.

Cap off shower pipe 

(5)

.

For support, use pipe BRACES 

(6)

 secured to wooden braces.

With valve turned off, turn on water supplies. Check for leaks.

COLD

HOT

Cut a 4" dia. hole in the shower stall.

Drill two additional 1" holes to allow

access to the stops.

Remove PLASTER GUARD 

(3)

, rotate

180˚ so that indicated screw holes fit

MANIFOLD 

(2)

. Push CAP 

(4)

 on valve, place

ESCUTCHEON on and attach with screws.

1

6

5

3

4

2

See Roughing-in diagram before starting.

Connections are:

  1/2" female NPT for threaded inlets

Connect RISER PIPE 

(1)

 to MANIFOLD 

(2)

top outlet marked "SHR".

For proper positioning the finished wall

must be within side wall of PLASTER

GUARD 

(3)

. Secure valve body to wall

support.

2

2 1/8" D.

(54mm)

1/2" NPT

(13mm)

FINISHED WALL

OPTIONAL TO

FINISHED

FLOOR 

USUALLY

BETWEEN

72'' AND 84"

(1829mm TO

2134mm)

1-5/8" TO 3-1/4"

(41mm TO 83mm)

74" FOR HEAD

CLEARANCE

(OPTIONAL)

(1880mm)

16 5/8"

(422mm)

9 5/8"

(244mm)

3/8"

(10mm)

8" D.

(203mm)

8" D.

(203mm) 

TUB

"SEE

ILLUSTRATION"

BELOW

ROUGHING-IN DIMENSIONS

5-1/2"

(140 mm)

THREADED INLETS (STOPS)

OUTLETS 1/2" NPT

INLETS 1/2" NPT

3-3/8"

(86mm)

SHW

BOTTOM OF

TUB

OR SHOWER

STALL

(48" TO 54"

OPTIONAL)

1219mm to

1372mm

INSTALL VALVE COVER

When finished tiling the wall, remove

PLASTER GUARD 

(1)

.

Push CAP 

(2)

 over VALVE CARTRIDGE 

(3)

until seated against stop.

(Spline in CAP 

(2) 

must fully

engage spline on cartridge stem). 

1

2

3

INSTALL TRIM

1

2

3

4

OFF

H

OT

CO

LD

“OFF” AT BOTTOM

Install ESCUTCHEON 

(1)

 onto CAP 

(2)

and push flush against finished wall.

Align mounting holes in ESCUTCHEON 

(1) 

with

with threaded mounting holes in valve body.

Secure ESCUTCHEON 

(1) 

with SCREWS

 (3).

Push DIAL PLATE 

(4)

 onto CAP 

(2).

    

 

    

Adjustable Wrench

Pipe Wrench

Hammer

THREADED

MOUNTING

HOLES