RECOMMENDED TOOLS
Teflon Tape
Phillips Screwdriver
Regular Screwdriver
1
ROUGHING-IN
Turn off water at main supply.
CAUTION
When soldering, remove PLASTER GUARD, CARTRIDGES and CHECK
STOPS (IF PRESENT). When finished soldering, flush valve body, replace
cartridges, check stops (if present) and plaster guard to continue installation.
Use thread sealant or Teflon tape on threaded connections.
NOTE
If the valve is installed on a fiberglass or
other thin wall application, the PLASTER
GUARD
(3)
can be used as a support.
Connect hot and cold water supplies.
Cap off shower pipe
(5)
.
For support, use pipe BRACES
(6)
secured to wooden braces.
With valve turned off, turn on water supplies. Check for leaks.
COLD
HOT
Cut a 4" dia. hole in the shower stall.
Drill two additional 1" holes to allow
access to the stops.
Remove PLASTER GUARD
(3)
, rotate
180˚ so that indicated screw holes fit
MANIFOLD
(2)
. Push CAP
(4)
on valve, place
ESCUTCHEON on and attach with screws.
1
6
5
3
4
2
See Roughing-in diagram before starting.
Connections are:
1/2" female NPT for threaded inlets
Connect RISER PIPE
(1)
to MANIFOLD
(2)
top outlet marked "SHR".
For proper positioning the finished wall
must be within side wall of PLASTER
GUARD
(3)
. Secure valve body to wall
support.
2
2 1/8" D.
(54mm)
1/2" NPT
(13mm)
FINISHED WALL
OPTIONAL TO
FINISHED
FLOOR
USUALLY
BETWEEN
72'' AND 84"
(1829mm TO
2134mm)
1-5/8" TO 3-1/4"
(41mm TO 83mm)
74" FOR HEAD
CLEARANCE
(OPTIONAL)
(1880mm)
16 5/8"
(422mm)
9 5/8"
(244mm)
3/8"
(10mm)
8" D.
(203mm)
8" D.
(203mm)
TUB
"SEE
ILLUSTRATION"
BELOW
ROUGHING-IN DIMENSIONS
5-1/2"
(140 mm)
THREADED INLETS (STOPS)
OUTLETS 1/2" NPT
INLETS 1/2" NPT
3-3/8"
(86mm)
SHW
BOTTOM OF
TUB
OR SHOWER
STALL
(48" TO 54"
OPTIONAL)
1219mm to
1372mm
INSTALL VALVE COVER
When finished tiling the wall, remove
PLASTER GUARD
(1)
.
Push CAP
(2)
over VALVE CARTRIDGE
(3)
until seated against stop.
(Spline in CAP
(2)
must fully
engage spline on cartridge stem).
1
2
3
INSTALL TRIM
1
2
3
4
OFF
H
OT
CO
LD
“OFF” AT BOTTOM
Install ESCUTCHEON
(1)
onto CAP
(2)
and push flush against finished wall.
Align mounting holes in ESCUTCHEON
(1)
with
with threaded mounting holes in valve body.
Secure ESCUTCHEON
(1)
with SCREWS
(3).
Push DIAL PLATE
(4)
onto CAP
(2).
Adjustable Wrench
Pipe Wrench
Hammer
THREADED