background image

TRANSFER

KNOB

H 9 6 5 8 6 3

3

INSTALL VALVE BODIES

INSTALL HANDLES

2

2a

HOSE ASSEMBLY

HAND SHOWER ASSEMBLY

Note: Back flow prevention and 2.5 GPM flow

restrictions are included with all Roman tub

sets with hand shower

Insert FIBER WASHERS 

(1)

 into COUPLING NUTS 

(2)

 of SUPPLY

HOSES 

(3)

 and tighten.

1-1/2'' MAX.

"O" RING

Thread LOCKNUT 

(8)

 to bottom of VALVE BODY 

(2)

. Make sure

FIBER WASHER 

(9)

 and RUBBER WASHER 

(10)

 are installed.

Insert VALVE BODY 

(2)

 through mounting hole from underside

of tub deck or mounting surface. 

Note: VALVE BODY marked Hot is installed in the left Mtg. hole,

VALVE BODY marked Cold in the right when facing front of fitting.

Maximum mounting surface thickness is 1-2/4".

HANDLE ASSEMBLIES 

(1, 1A)

 are installed on VALVE BODIES 

(2)

and must be removed to install VALVE BODIES 

(2)

 from under tub

deck or mounting surface.
To remove HANDLE ASSEMBLY 

(1)

, unthread HANDLE BASE 

(3)

 with

LEVER 

(4)

 from VALVE BODY 

(2)

. Pull HANDLE ASSEMBLY 

(1)

 off

VALVE STEM 

(5)

.  

Unthread and remove MOUNTING RING 

(6)

 and SPACER 

(7)

.

From top install SPACER 

(7)

 onto VALVE BODY 

(2)

. Thread

MOUNTING RING 

(6)

 on VALVE BODY 

(2)

 until seated tightly against

SPACER 

(7)

. Set VALVE BODIES 

(2)

 so that their outlets are facing

toward SPOUT TEE 

(11)

 and then tighten LOCKNUT 

(8)

 using 35mm

or adjustable wrench.
Insert FIBER WASHERS 

(12)

 into COUPLING NUTS 

(13)

 of

SUPPLY HOSES 

(14)

 and tighten making water tight connection.

Important: Loop SUPPLY HOSES 

(14)

 as illustrated so they do not kink. 

6

1

3

4

8

12

HOT

13

14

9

11

10

7

5
2

JADO

"O" RING

TUB DECK OR

MOUNTING SURFACE

Turn VALVE BODIES 

(2)

 to off position. Align HANDLES as shown or as desired

and install HANDLE ASSEMBLY

(1, 1A)

 onto VALVE STEM 

(5)

. Thread HANDLE

BASE 

(3)

 onto VALVE BODY 

(2)

 until seated tightly against mounting surface. 

Drop SPRAY HOLDER 

(4)

 into the fourth hole of the tub 

ledge or deck (12" max from SPOUT center) directed

towards tub center. Be sure O-RING 

(5)

 is properly

seated in ESCUTCHEON 

(6)

. Install RUBBER

WASHER 

(7)

, FIBER WASHER (8) and LOCKNUT

(9)

 from underside of mounting ledge. Secure

SPRAY HOLDER 

(4)

 by tightening LOCKNUT 

(9)

.

Add SEAL WASHER 

(10)

 and connect COUPLING

NUT 

(11)

 of BRAIDED HOSE 

(12)

 to outlet nipple. 

Tighten firmly. Tighten SPRAY REST 

(19)

Slip SHOWER HOSE 

(13)

 with COUPLING

NUT 

(14)

 through SPRAY HOLDER 

(4)

 and

ESCUTCHEON 

(6)

.

Install SEAL 

(15)

 into COUPLING NUT 

(14)

. Connect

COUPLING NUT (15) to HOSE NIPPLE (16) and tighten.

 

INSTALL second SEAL 

(15)

 and connect HAND

SHOWER 

(17)

 to SPRAY HOSE END 

(18)

. Hand tighten.

14

2

2

1

1

11 

12 

13

3

3

10

15

8

BRAIDED

HOSE

16 

15 

5

6

4

OUTLET

NIPPLE

9

18

7

3

HOT

COLD

3/4" D.

 

19

17

Reviews: