background image

SMALL

END

LARGE

END

LARGE

END

VALVE

OUTLET

VALVE

OUTLET

PUTTY

1

2

3

H 9 6 5 12 5 F

5

6

INSTALL SUPPLY HOSES

INSTALL SPRAY BODY

INSTALL HANDLES

Connect small end of SUPPLY HOSES 

(1)

 TO "Y" ADAPTER 

(2)

and larger end to each VALVE OUTLET.

Important: Loop SUPPLY HOSES 

(1)

 as illustrated

so they do not kink.

Connect one end of SPRAY HOSE 

(7) 

to HOSE ADAPTER 

(8)

 

and the other end to shank of SPRAY BODY 

(3)

. Tighten hose

connections to make a water tight seal. 

7, 8

6

2

4

5

1

3

9

10

11

12

Hex wench, supplied

BIDET

MOUNTING

SURFACE

DIVERTER

For Cross handles:

 Turn

VALVE to off position and align

CROSS HANDLE 

(5)

 as shown.

Install CROSS HANDLE 

(5)

onto VALVE STEM 

(3)

 and

tighten HANDLE SCREW 

(6)

.

Insert HOT INDEX 

(7)

 into

left CROSS HANDLE and COLD

INDEX 

(8)

 into right CROSS

HANDLE 

(5)

.

For Diverter handle:

 Install DIVERTER HANDLE 

(9)

 onto VALVE

STEM 

(10)

 of DIVERTER. Secure with DIVERTER HANDLE SCREW

(11)

. Thread HANDLE CAP 

(12)

 onto DIVERTER HANDLE 

(9)

.

For Lever Handles:

 Install

FRICTION WASHER 

(1)

 onto

base of LEVER HANDLE 

(2)

.

Turn VALVE to off position and

align LEVER HANDLE 

(2)

 as

shown. Install LEVER HANDLE

(2)

 onto VALVE STEM 

(3)

and tighten SET SCREW 

(4)

with HEX WRENCH supplied. 

JADO

JADO

1

Apply putty to the underside of SPRAY BODY

FLANGE 

(3)

 and install SPRAY BODY 

(3)

 into

spray hole of Bidet.

From underside of Bidet install RUBBER WASHER 

(4)

,

FIBER WASHER 

(5)

 and LOCKNUT 

(6)

 onto shank of SPRAY

BODY 

(3)

. Tighten LOCKNUT 

(6)

 to make water tight seal.

4

8

5
6

7

7

Connect water supplies to FAUCET 

(1)

 with

1/2" IPS FLEXIBLE SUPPLIES 

(2)

 or 3/8"

O.D. BULL-NOSE RISERS 

(3)

. Use adjustable

wrench to tighten connections. Do not over

tighten. Be careful not to kink copper supply

when bending. Use tubing cutter to cut to

proper length.

Supply connections are made after bidet

has been installed.

3

2

HOT

HOT

COLD

FRONT

COLD

FERRULE

COUPLING

NUT

1

NOTE: FLEXIBLE SUPPLIES ARE NOT INCLUDED

AND HAVE TO BE PURCHASED SEPARATELY.

WATER SUPPLY CONNECTIONS

APPLY SEALANT 

OR TEFLON TAPE

4

A FOAM SEAL 

(1)

 is installed on underside of FLANGE 

(2)

. (Plumbers

Putty may be used in place of FOAM SEAL 

(1)

 if desired.)

Apply sealant or Teflon tape to threads of TAILPIECE 

(10)

 and

thread into DRAIN BODY 

(7)

 making a water tight seal.

Drop FLANGE 

(2)

 into LAVATORY DRAIN 

(3)

. From below assemble

RUBBER GASKET 

(4)

, PLASTIC WASHER 

(5)

 and LOCK NUT 

(6)

 onto

DRAIN FLANGE 

(2)

. Do not tighten fully.

INSTALL POP-UP DRAIN

FIG. 4a

FIG. 4b

FIG. 4c

FIG. 4c

FIG. 4a

FIG. 4b

1

4

3

2

5

6

7

8

6

9

2

Adjust STOPPER 

(13)

 height by repositioning POP-UP ROD 

(16)

 in SWIVEL 

(15)

and tightening SET SCREW 

(18)

.

Assemble POP-UP SWIVEL 

(15)

 to PIVOT ROD 

(11)

 but do not tighten.

Drop POP-UP ROD 

(16)

 through other hole in POP-UP SWIVEL 

(15)

 and

tighten SET SCREW 

(17)

Assemble PIVOT ROD 

(11)

,WASHER 

(20)

 and PIVOT NUT 

(12)

 as shown. Install

CONCAVE WASHER 

(19)

 into PIVOT ROD OPENING 

(9)

 if not preinstalled.

Hand tighten PIVOT NUT 

(12)

. Drop STOPPER 

(13)

 into drain.

(

To vandal proof drain rotate STOPPER 

(13)

 so PIVOT ROD 

(11)

 goes

through EYE 

(14)

 of STOPPER 

(13)

. Make connection to "P" TRAP.

Inspect inside DRAIN BODY 

(7)

 that SEAL 

(8)

 is installed. Thread

DRAIN BODY 

(7)

 tight against FLANGE 

(2)

 to make a water tight seal.

10

9

7

6

12

19

16

15

17

18

2

10

14

13

11

20

The PIVOT ROD OPENING 

(9)

 in DRAIN BODY 

(7)

 should face the rear

of the lavatory. Tighten LOCK NUT 

(6)

 on FLANGE 

(2)

 to make a water

tight connection with channel locks. Do not over tighten.

Reviews: