5
Put the plug in the socket,
is charging lamp.
is lighting when charging.
Show voltage
:
after power on and on“0”, at the same time press <ON /ZERO> and <TARE > three seconds,
now show the battery voltage, press <SET/0~9> to exit.
4-9
Parameter setting
Press <SET/0~9> for 3 seconds to enter setting and show main menu. Press <SET/0~9> to choose
continuously. It displays as bellow:
rAngE (set limit)
UnItS (choose unit)
A-OFF (choose auto power off)
FILt (set display mode)
Zero (set auto zero)
bUZZE (set buzzle)
d (choose division)
LU- (brightness adjusting)
4-9-1 rAngE (set upper and low limit)
4-9-1-1 When it shows rAngE, press <TARE> to set limit values. Press <SET/0~9> to choose ON or OFF.
“ON” is start limit function. “OFF” is Exit limit function. Press <TARE> to confirm.
4-9-1-2 When choose “on” , Press <tare> to enter to set limit value. “under” lamp is lighting and max figure is
blinking. Press <set/0~9> once to add numbers. Press <tare> to confirm. When finishing setting under
values it will auto exit and then set “over”(same as set under limit).After finish setting, it will back into
weighing.
4-9-1-3 When low limit > high limit, it displays off, and then exit.
4-9-1-4 Alarming indicate: m is the weight.
When m
≥
high limit, “over” lamp is lighting and flickering.
When low limit <m<high limit, “accept” lamp is lighting (not flickering).
When m
≤
low limit, “under” lamp is lighting.
Caution:
when the display is not stabilization, no lamp lights.
4-9-2 Units
4-9-2-1 when it displays units, press <tare> to enter and press <set/0~9> to change units. Then press <tare>
to confirm. Units: h9(kg), pcs(counting), lb.lb (decimal pounds)