background image

 

Content 

 

1

Introduction

…………………………………………………………………………. 

2

Precautions

………………………………………………………………………. 

3.Product Introduction

   

3-1 Specifications & Features…………………………………………………………. 
3-2 Front Panel………………………………………………………………………….. 
3-2-1 Display…………………………………………………………………………….. 
3-2-2 Keyboard………………………………………………………………………….. 
3-3 Rear Panel………………………………………………………………………….. 
3-4 Power supply………………………………………………………………………... 

 
 





4. Installation

 

4-1 Load cell connection……………………………………………………………….. 
4-2 Assembly Description of Upright Pole……………………………………………. 

 

 

5

Setting Mode

 

5-1 Maximum Weighing Capacity & Division Setting……………………………….. 
5-2 Function Setting……………………………………………………………………. 
5-3 Description of Parameter Values………………………………………………….. 

 
 


6. Calibration

………………………………………………………………………… 

10 

7

.

Operation

 

7-1 Weighing…………………………………………………………………………….. 
7-2 Tare………………………………………………….............................................. 
7-3 Check Weighing……………………………………………………………………. 
7-4 Simple Counting…………………………………………………………………… 
7-5 Input Demand………………………………………………………………………… 
 

 
 
11 
11 
12 
13 
13 

8.

 

Error message

 

and Trouble Shootings

……………………………………..

 

14 

 
 
 
 
 
 
 
 

CAN DIEN TU TAN HIEP THANH

www.tanhiepthanh.com.vn

Summary of Contents for JWI-3100

Page 1: ...oad cell connection 4 2 Assembly Description of Upright Pole 4 5 5 Setting Mode 5 1 Maximum Weighing Capacity Division Setting 5 2 Function Setting 5 3 Description of Parameter Values 6 7 7 6 Calibration 10 7 Operation 7 1 Weighing 7 2 Tare 7 3 Check Weighing 7 4 Simple Counting 7 5 Input Demand 11 11 12 13 13 8 Error message and Trouble Shootings 14 CAN DIEN TU TAN HIEP THANH www tanhiepthanh com...

Page 2: ...se strong wind and vibration which might cause incorrect reading Avoid sudden temperature changes suitable operating temperature is between 0 40 Disconnect the power supply when cleaning the indicator Do not immerse the indicator in water or other liquids 3 Product Introduction 3 1 Specification and Feature Specification Model JWI 3100 Input sensitivity 0 2uV DIV Input voltage range 2mV to 20mV Lo...

Page 3: ...djustable stand for bench scale 3 2 Front Panel 3 2 1 LCD Display Low battery indication ZERO Center of Zero Indication The zeroing range is 2 of scale capacity Stable indication TARE Symbol points at TARE when the weight of the container is tared Preset Tare Symbol points at Preset Tare when Tare value entered via keypad NET Net weight Gross weight minus Tare Symbol points at NET when Tare or Pre...

Page 4: ...t weight by turns Long press for the choice of sampling Shift key shift leftwards PRINT HI key The number increases one when value setting Print out when setting manual print Long press higher limit initials higher limit setting HOLD LO key The number decreases one when value setting Remain the weighing display in the window 5 options Long press lower limit initials lower limit setting TARE key Ta...

Page 5: ...wer ON OFF switch 3 4 Power supply 1 Switching power supply 100V 240V 2 6V 4A Internal Rechargeable Battery Power Consumption 330mW with backlight about 70 hours available Low battery warming When appears in the upper left corner of the weight window the battery power requires recharging The charge lamp turns green from red when the recharging is completed which takes about 8 hours Disconnect the ...

Page 6: ...upright pole 2 insert the upright pole into the rod seat and then lock it with two screws 5 Step 2 After threading the Load Cell wire through the bracket 3 attach the bracket to the upright pole and then lock it with the screw 6 Note if the load cell connector is too big to thread through the bracket separate the bracket by removing the knob pole 7 see the following pictures LOAD CELL CONNECTION P...

Page 7: ...powering on the scale When the window displays 300 00 KG 300 00 KG 300 00 KG 300 00 KG release the key and it enter the capacity setting 2 Press PRINT HI or HOLD LO to choose common used capacity Press G N or TARE to shift the decimal point and press UNIT to choose kg g lb or 台斤 Note if not the needed capacity long press UNIT SET until the number leftmost is blinking to set the capacity casually P...

Page 8: ...LO to shift the decimal point Press ZERO ESC to save and enter into calibration setting 4 The window dispays CAL Press TARE to enter calibration setting while LONG press ZERO ESC to exit and return to weighing mode 5 2 Function Setting 1 Press and hold UNIT SET while powering on or long press UNIT SET under normal weighing mode to enter function setting 2 Press G N or TARE to shift between the fun...

Page 9: ...9d 5 Unit setting Init Press key UNIT SET to select the default unit when powering on the scale kg lb final final keep the final being used unit when power off Use Press key UNIT SET to select the weighing unit on Enable the unit off Disable the unit Note Press UNIT SET to choose the weighing unit Press G N or TARE to enable disable the unit 6 Zero range d0 d1 d2 d3 d4 and d5 d scale division 7 Ho...

Page 10: ...les exceeds the lower limit and the weight is equal or more than 20d OK There will be a warning sound when the weight of articles is between the upper and lower limit including the upper and lower limits and the weight is equal or more than 20d OUT There will be a warning sound when the weight of articles is beyond the upper lower limit and the weight is equal or more than 20d no beep no beep 11 E...

Page 11: ... display the previous weight when powering on again OFF not display the previous weight when powering on again 18 parameter initialization Press UNIT SET twice to begin initialization until the window displays OK 6 Calibration Note Before calibration please set the capacity first The unit used in calibration is the one that has been set before During the calibration procedure LONG press ZERO ESC t...

Page 12: ...complete Repeat this step to complete multi point calibration 6 Press ZERO ESC to save After the window displays it will return to normal weighing mode 7 Operation 7 1 Weighing Begin with no load on the scale the display reading zero Place item s to be weighed on the scale The display shown is 1 000kg gross weight The desired weighing unit should be selected before weighing refer to section 5 5 7 ...

Page 13: ...the container from the total value 5 Press TARE or key ZERO ESC with no load on the pan if the tare function is to be cancelled 7 3 Check Weighing Use this mode to compare the weight of an item to Lower and Upper limits When the check weighing mode is enabled the indicator will turn on Upper limit setting 1 Long press key PRINT HI The scale is now in Digital inputting mode with the left most digit...

Page 14: ...nting 1 Press key UNIT SET to select the unit PCS under the weighing mode 2 Press key G N the ex factory default sample quantity 10 pcs is displayed 3 Use key PRINT HI or HOLD LO to choose the sampling amount Available options are 0 20 50 100 200 500 1000 pieces 4 Put the corresponding samples on the weighing pan and then press key TARE SAMP is displayed momentarily before the display reverts to t...

Page 15: ... the capacity first then adjust resolution ERR2 Initial zero point exceeds 30 of full load 1 Remove the obstacle article under the pan 2 Replace the load cell or contact the maintenance department ERR3 Exceed the A D resolution range 1 Replace A D 2 Replace the load cell or contact the maintenance department ERR4 EEPROM failure Re weld EEPROM or contact the maintenance department ERR5 Overload con...

Page 16: ...ic demand about the format conduct as follows 1 As for BRICH GODEX ZEBRA printers the factory designs the format as planned and email to the user Add the format into the previous format file via computer Then it is successful to add the new format and able to print the new format 2 As for DMP printer it needs to change the scale design G W 1 000 kg T W 0 500 kg N W 1 500 kg 1 000 kg CAN DIEN TU TA...

Page 17: ...JWI 3000 16 CAN DIEN TU TAN HIEP THANH www tanhiepthanh com vn ...