JWE
8
2) Press key
MODE
to enter the zero point calibration mode.
3) Wait till
appears, put weights of 1/3 of full load on the weighing pan and press
down key
TARE
E.g., for JWE-3K ,1/3 of full load is 1kg.
4) Wait till
appears, and then put weights of 2/3 of full load on pan and press down
key
TARE
E.g., for JWE-3K, 2/3 of full load is 2kg.
5) Wait till
appears, then put weight of full load on and press
TARE
E.g., for
JWE-3K, full load is 3kg.
6) The calibration procedure ends up with a symbol of “PASS”.
7) Remove all the weights, and then press key
ZERO+
to return to weighing mode.
7. Setting Mode& Description of Parameter Values
Setting Mode
1) Long-press key
MODE
while powering on the scale to enter setting mode. The screen
displays “CAL”, then release the keys.
2) Press key
MODE
to circle through setting modes.
3) Press key
M+MR
to choose function.
4) Press key
MC/SET
switch on and off the chosen function. Press key
ZERO+
to save the
setting and back to the weighing mode. If more settings are needed, press key
MODE
again.
Description of Parameter Values
1)
Calibration See “7. Calibration”
2)
Set the active weight unit. The following setting are available:
kg, g, lb, lb-oz,
斤
,
台斤
,
港斤
,pcs and % .
(Enable);
(disable)
3)
Set the init weight unit. The following setting are available:
kg, g, lb, lb-oz,
斤
,
台斤
,
港斤
,pcs and %.
(Enable);
(Disable)