    1 

CONTENTS 

 

PRECAUTIONS .................................................................................. 3 

INSTALLATION .................................................................................. 4 

FUNCTIONS 

ZERO ........................................................................................... 10 

TARE ........................................................................................... 11 

PRE-TARE ................................................................................... 13 

AUTO TARE ................................................................................ 15 

SELECTION OF WEIGHING UNIT ............................................. 17 

UNIT IN USE AND INITIAL WEIGHING UNIT SETTING ............ 17 

ACCUMULATION ................................................................. .......18 

ACCUMULATION MODE .......................................................... ..20 

MAX ACCUMULATION SETTING ............................................ ..21 

SIMPLE COUNTING ................................................................... 22 

PERCENTAGE ............................................................................ 23 

HI / LO CHECKING ..................................................................... 25 

SERIAL NUMBER ....................................................................... 27 

STARTING SERIAL NUMBER SETTING ................................... 28 

MAX SERIAL NUMBER SETTING ............................................. 29 

TIME AND DATA SETTING ......................................................... 30 

PRINT .......................................................................................... 31 

PRINT FORMAT SETTING ......................................................... 32 

SPACE BETWEEN LINES WHEN PRINTING ............................ 33 

PRINTING MODE SETTING ....................................................... 34 

Summary of Contents for JIK-8

Page 1: ...E AND INITIAL WEIGHING UNIT SETTING 17 ACCUMULATION 18 ACCUMULATION MODE 20 MAX ACCUMULATION SETTING 21 SIMPLE COUNTING 22 PERCENTAGE 23 HI LO CHECKING 25 SERIAL NUMBER 27 STARTING SERIAL NUMBER SETTING 28 MAX SERIAL NUMBER SETTING 29 TIME AND DATA SETTING 30 PRINT 31 PRINT FORMAT SETTING 32 SPACE BETWEEN LINES WHEN PRINTING 33 PRINTING MODE SETTING 34 ...

Page 2: ...0 Connect JIK 8 to JOW and LED 42 CAPACITY RESOLUTION SETTING 43 DIVISION CONFIGURATION CHART 45 TESTING MODE 46 ERROR MESSAGES 47 LCD CHARACTERS 48 CONNECTER 49 DATA PROTOCOL 49 RELAY MODULE DIAGRAM 50 DUAL PLATFORM OPERATION CH1 CH2 51 PRODUCT SPECIFICATIONS 52 ASSEMBLY MANUAL OF JIK INDICATOR AND SUPPORT STAND 53 FIXING SCREW INSTRUCTION FOR JIK XSX 54 SINGLE POINT CALIBRATION FOR WEIGHT 55 ...

Page 3: ...s Near vibrating rotating or reciprocating equipment Near magnetic fields or equipment that generates magnetic fields On a rough work surface Leveling the scale when the indicator is connected to a platform Always adjust the scale to a level position with level adjusters until the bubbles appear in the center circle of the level indicator Battery Recharged the battery whenever the symbol is flashi...

Page 4: ......

Page 5: ...ded screws 2 Pull load cell cable through indicator supporter 4 to connect to the indicator 3 Install Indicator supporter 4 and indicator stand 3 together 4 Adjust the indicator to adequate viewing angle and tighten the screws located on each side of the Indicator 1 Load Cell male connector 7 pin 2 Load Cell female connector 7 pin 3 Indicator Stand 4 Supporter between frame and indicator 5 Pole 6 ...

Page 6: ......

Page 7: ...ication Additional weighing units Battery Power is weak Explanation of each key Posit ion keys Main function Secondary functions Turns the indicator on or off 1 To delete the accumulation weights or certain number of accumulated weight 1 Change the digit when in parameter mode decreased 2 Change the number when in HI LO checking mode 3 Setting of date time 2 Accumulation 1 Change the digit when in...

Page 8: ......

Page 9: ......

Page 10: ...he left diagram When the display is at zero this sign will appear 2 Press to return to zero when the display is without the sign 3 Now the sign appear and the scale is in zero point Remarks The range of zero point is 2 of the max capacity Example the zero range of 60kg is 1 2kg ...

Page 11: ......

Page 12: ...12 8 Remove all objects from the weighing pan and wait for the zero sign to appear 9 Press key 10 The NET and TARE signs will disappear and the scale now UHWXUQ V WR zero point Remarks Weighing Range Maximum Range Tare Range ...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ... will be shown as kg when using division 1g the unit will be shown as g UNIT IN USE AND INITIAL WEIGHING UNIT SETTING 1 Press and hold key without release and turn on the scale Until display show then release 2 Press key for selection of different weighing unit there are 4 weighing units kg lb pcs 3 Use key to select the weighing unit to be ON in used or OFF not in used ...

Page 18: ......

Page 19: ......

Page 20: ......

Page 21: ......

Page 22: ...s reach 20 times the internal alarm will beep and no more accumulations are allowed The display will show ACC20 flashing as a signal indicating that maximum accumulations is reached this function applied to all accumulation mode SIMPLE COUNTING 1 Press key to select the pcs as weighing unit 2 Place the sampling quantity on the pan You can choose the sampling quantity as 10 25 50 100pcs only ...

Page 23: ......

Page 24: ...s 10 flashing and the operation PHVVDJH GLVSOD ZLO indicate now is in sampling mode 4 Press or key to select the sampling quantity For example if you select 50 for sampling quantity 50 flashing will be displayed on the screen 5 Press key to complete the sampling procedures Now the scale is ready for percentage weighing Put object on the pan for percentage weighing ...

Page 25: ......

Page 26: ......

Page 27: ...o weighing mode display will now show for serial number except if the setting is in mode Mode of serial number No action The serial number plus 1 1 when the stable sign appear Serial number plus 1 1 when the weight is in between HI LO checking limits This function is valid even if the HI LO checking function is disabled Pause No adding of serial number but display will still show the last serial n...

Page 28: ......

Page 29: ...et before by pressing it will show the first serial number 2 Press key display will show symbol on the right corner meaning the scale is in setting of maximum serial number mode 3 Press or key to move the cursor to the digit wish to change default 99999 4 Use or key to change the number For example maximum serial number is 100 and key in ...

Page 30: ...he serial number reaches the maximum serial number it will restart from serial number 1 again Remark max serial number must starting serial number TIME AND DATE SETTING 1 Under normal weighing mode press key display will show the time 2 Press key to enter to time setting mode Last digit is flashing 3 Press or key to move the cursor and press or key to change the setting ...

Page 31: ......

Page 32: ...as set to the scale will then enter to HI limit setting 2 Press or key to move the cursor and use or key to key in number In total there are 100 print format available for choose 3 Press key to complete the chosen and return to normal weighing mode Note 1 There are three options of printers available SH 24 dot matrix printer SH 16 BP 443D Label printer or EZ 2P Label printer 2 U KEY Connector used...

Page 33: ... choose the setting to SH 24 NORMAL 2 Press key and display shows The operation message display will show 3 Press key display show 7KH RSHUDWLRQ display will show 4 Press or key to set the number of empty lines space when printing minimum 0 maximum 9 5 Press key to complete the setting and return to normal weighing mode ...

Page 34: ...lay will show the printing mode Example 3 Use or key to select the printing mode refer to the below mentioned chart 4 Press key to save changes and return to normal weighing mode Print manually by pressing PRINT key Print continuously when connecting to PC or large LED Display No action Print after stable symbol appear Print when weight is between HI LO limits this function is valid even if HI LO ...

Page 35: ......

Page 36: ... of SH 24 Printing Formats When appear under display of accumulation press key the print out will like as following Remark Without any commands the printer are able to print format Prt00 Prt07 when connected to a parallel port printer ...

Page 37: ......

Page 38: ......

Page 39: ...V03 JIK 8 User Manual 39 2 Press or key to choose desired setting 3 When setting is complete press key and return to normal weighing mode ...

Page 40: ...with light tower beeps when the range is between HI LO Option Relay with light tower beeps when the range is out of HI LO P2 HOLD able to hold the displayed weight after load is remove No action of Hold Able to hold the displayed weight and print at the same time after pressing print key when there is loading Press Key to clear P3 Printer type Setting of this parameter determines the data format f...

Page 41: ...ing of this parameter determines the RS 232 transmission data format P7 Backlight No Backlight Backlight is on always Backlight when stable sign appear Off automatically 5 seconds after stable weighing Auto backlight is actuated when weight loading is over 20d P8 JOW switches Channel 2 for JOW Channel 2 for SCALE 2 P9 Channel Channel 1 Channel 2 Dual Channel Note the default setting for A19 12C wh...

Page 42: ......

Page 43: ......

Page 44: ... This means that setting of capacity resolution is completed Example Turn off the scale and turn on again Note Maximum capacity to be set for this indicator is 400000kg Minimum division to be set for this indicator is 0 01g Whenever the capacity resolution is set or changed be sure to re calibrate according to calibration procedure located in service manual ...

Page 45: ......

Page 46: ......

Page 47: ...re the pan is on the scale or perform the 3 points calibration 2 Check the connections of wires E4 Unstable zero point 1 Make sure there is no winds or vibration 2 Check the connections of wires E5 1 Load cell spec not compatible 2 calibrating weights mistake 1 Replace with a compatible load cell 2 Change with correct calibrating weights E6 Load cell read out always the same 1 Check if load cell w...

Page 48: ......

Page 49: ......

Page 50: ...r Manual 50 RELAY MODULE DIAGRAM Relay Output Alarm COM N C N O HI COM N C N O OK COM N C N O LO COM N C N O Relay Contact Spec 1A 24VDC 0 5A 125VAC 0 25A 250VDC Reminder suggest to add a ferrite core on the cables ...

Page 51: ...ion and perform calibration of platform 2 6 Turn off the indicator now and then restart 7 Now the display is for platform 1 CH1 now in platform 1 CH1 8 Press for switch between CH1 and CH2 Features 1 Each platform has respectively Serial Number and Max Serial Number 2 Each platform has respectively 10 sets of Hi Lo 5 sets of Auto Tare and 5 sets of Pre Tare memories 3 Printing format for two platf...

Page 52: ......

Page 53: ...justable screw to pass through mounting hole illustrator I 2 Put M6 washer onto adjustable screw illustrator II 3 Rotating the star turning button into adjustable screw illustrator III 4 Adjust the indicator to the best view and then rotate it tight via star turning button illustrator VI ...

Page 54: ......

Page 55: ...enter into the next step Press or key to shift the flickering digit left or right press key to set any value between 1 2 5 after setting press key to save and show the offset value press WKHZHLJKLQJSDQJHQWO LIWKHYDOXHFKDQJHVLW VQRUPDO Press key to perform zero point calibration when CAL on the lower left stops flickering zero point calibration is completed with CAL kg shown If the show value is ve...

Page 56: ......