14
E1:
E1:
E1:
E1: No
No
No
No feedback
feedback
feedback
feedback from
from
from
from controller
controller
controller
controller or
or
or
or speed
speed
speed
speed sensor
sensor
sensor
sensor
1. Check the condition of cables and ensure that all plugs are connected
between the motor controller and display.
2. Check that the speed sensor and magnet are in correct alignment and that
there are no obstructions on the magnet. (The magnet can be found on the
front roller near the motor belt).
3. If the running belt moves then displays the E1 error after 10 seconds, replace
the speed sensor.
4. If the running belt does not move, replace the controller.
E3:
E3:
E3:
E3: Self-checking
Self-checking
Self-checking
Self-checking failure
failure
failure
failure
1. If the running belt does not move, replace the controller.
2. Ensure that all plugs are connected between the motor controller and display.
3. Check that the speed sensor and magnet are in correct alignment and that
there are no obstructions on the magnet. (The magnet can be found on the
front roller near the motor belt).
No
No
No
No Power
Power
Power
Power
1. Check fuses (They are located on the controller under the motor cover )
2. Check power outlet (Plug something else into the power outlet to ensure that
the power outlet is working correctly).
3. Check Power Cable (You may need to take it to an electrician).
6.
6.
6.
6. EXERCISE
EXERCISE
EXERCISE
EXERCISE GUIDE
GUIDE
GUIDE
GUIDE
PLEASE
PLEASE
PLEASE
PLEASE NOTE:
NOTE:
NOTE:
NOTE: Before
Before
Before
Before beginning
beginning
beginning
beginning any
any
any
any exercise
exercise
exercise
exercise program,
program,
program,
program, consult
consult
consult
consult you
you
you
you
physician.
physician.
physician.
physician. This
This
This
This is
is
is
is important
important
important
important especially
especially
especially
especially if
if
if
if you
you
you
you are
are
are
are over
over
over
over the
the
the
the age
age
age
age of
of
of
of 35
35
35
35 or
or
or
or
individuals
individuals
individuals
individuals with
with
with
with pre-existing
pre-existing
pre-existing
pre-existing health
health
health
health problems.
problems.
problems.
problems.
The
The
The
The pulse
pulse
pulse
pulse sensors
sensors
sensors
sensors are
are
are
are not
not
not
not medical
medical
medical
medical devices.
devices.
devices.
devices. Various
Various
Various
Various factors,
factors,
factors,
factors, including
including
including
including the
the
the
the
user
user
user
user’’’’s
s
s
s movement,
movement,
movement,
movement, may
may
may
may affect
affect
affect
affect the
the
the
the accuracy
accuracy
accuracy
accuracy of
of
of
of heart
heart
heart
heart rate
rate
rate
rate readings.
readings.
readings.
readings. The
The
The
The
pulse
pulse
pulse
pulse sensors
sensors
sensors
sensors are
are
are
are intended
intended
intended
intended only
only
only
only as
as
as
as an
an
an
an exercise
exercise
exercise
exercise aid
aid
aid
aid in
in
in
in determining
determining
determining
determining heart
heart
heart
heart
rate
rate
rate
rate trends
trends
trends
trends in
in
in
in general.
general.
general.
general.