33
TROUBLESHOOTING
(also refer to the chapter on
abnormal operating conditions
)
PROBLEM
PROBABLE CAUSE
SOLUTION
Dirty water
Filter clogged
Clean or replace filter
Insufficient water treatment
See chapter on water treatment
High content of solid material in water
Improper maintenance
See the instructions regarding
Maintenance
Excessive water consumption
Leak on delivery line,
Repair the leak
outlet line, connections
Excessive evaporation and/or
Use the spa cover
water overflow
Set a water temperature set point
lower
Low water flow
Low water level
Fill until covering
from the hydromassage nozzles
the highest nozzles
Filter clogged
Clean or replace filter
Adjustable jets partially closed
Open the jets
Suction or drain pipes
*
partially
clogged
Pump operates at a
*
speed that is too low
Pump gaskets worn or
*
damaged
Voltage too low
Contact an electrician or
the electric power utility
No water flow
No current
Turn main switches ON
Pump off
Press the button(s)
and/or
Motor not connected
Check the motor connection
Main switch turned off
Turn on the switch
Residual current operated circuit breaker
Reset the RCCB
(RCCB) has tripped
Faulty pump or motor
*
Pump and motor noisy
Filters clogged
Clean the filters
Water leakage on suction
Find and repair leaks