14
Electrical safety
Alimia is a safe appliance, manufactured according to
EN 60335.2.60,
EN 61000 and EN 55014
regulations and tested during production
to guarantee user safety.
I
Installation must be carried out by qualified and authorized personnel,
in compliance with the national provisions in force.
It is the responsibility of the installer to choose the ma-
terials in relation to their use, to carry the work out cor-
rectly, to check the condition of the system to which the
appliance is to be connected and its suitability, and to
guarantee safety when in use, for maintenance oper-
ations and system inspection.
I
spa products are Class “
I
” appliances and so they must be fastened
securely,
without intermediate joins
, to the electric mains and to
the protection system (earth system).
The electric system of the building must be provided
with a 0.03A differential switch and an efficient pro-
tection circuit (earth).
Check that the differential switch is working correctly by
pressing the test button (TEST), which must click.
몇
Parts incorporating electrical components, except
remote control devices, must be located or fixed so
that they cannot fall into the spa.
Live components and equipment must be out of
reach of individuals in the spa.
I
For electrical connections, the installation of a multiple-pole sec-
tion switch is compulsory (
i
4
). It must be positioned in a place that
complies with safety regulations and, in any case, which cannot be
reached by those using the spa.
It is mandatory to comply with this instruction. Any other pro-
cedure is prohibited.
몇
If the building’s electrical system is not able to
guarantee a stabile power supply, it is recommen-
ded to install a voltage stabiliser that suitably di-
mensioned for the required power upstream of the
equipment.
I
The disconnection devices must be installed in the power supply
network according to the installation instructions.
I
The installation of electrical devices and equipment (sockets,
switches, etc.) near the spa must be in compliance with legal stan-
dards and regulations in the country where the spa is installed.
I
For equipotential connection in compliance with specific national
regulations, the installer must use the provided terminal (
EN
60335.2.60
standard) on the electric wiring box (
i
4
), marked by
the symbol
. In particular, equipotential connection must be carried
out for all metal parts surrounding the mini-pool, for example, the wa-
ter and gas pipes and any surrounding metal under-frames etc.
I
The appliance comes equipped with an LED lighting system, in com-
pliance with Regulation
EN 62471:2009.
CAUTION! Before carrying out any maintenance oper-
ation, disconnect the appliance from the power supply
line.
Summary of Contents for alimia
Page 2: ......
Page 3: ...Italiano 10 English 12 Fran ais 15 Deutsch 17 Espa ol 20 23 Alimia Index...
Page 5: ...5 Alimia wood Alimia synthetic wood Alimia built in 2 i...
Page 6: ...6 76 cm 5 8 B B 3 4 1 1 2 2 3 3 i...
Page 8: ...8 12 cm Alimia synthetic wood synthetic wood wood OK 6 i 5 i...
Page 9: ...9 208 cm 5 1 4 3 3 2 2 4 5 7 i 8 i...
Page 26: ......
Page 27: ......