Electrical safety

Alimia is a safe appliance, manufactured according to

EN 60335.2.60,

EN 61000 and EN 55014

regulations and tested during production

to guarantee user safety.

I

Installation must be carried out by qualified and authorized personnel,

in compliance with the national provisions in force.

It is the responsibility of the installer to choose the ma-
terials in relation to their use, to carry the work out cor-
rectly, to check the condition of the system to which the
appliance is to be connected and its suitability, and to
guarantee safety when in use, for maintenance oper-
ations and system inspection.

I

spa products are Class “

I

” appliances and so they must be fastened

securely,

without intermediate joins

, to the electric mains and to

the protection system (earth system).

The electric system of the building must be provided
with a 0.03A differential switch and an efficient pro-
tection circuit (earth).
Check that the differential switch is working correctly by
pressing the test button (TEST), which must click.

Parts incorporating electrical components, except
remote control devices, must be located or fixed so
that they cannot fall into the spa.
Live components and equipment must be out of
reach of individuals in the spa.

I

For electrical connections, the installation of a multiple-pole sec-

tion switch is compulsory (

i

4

). It must be positioned in a place that

complies with safety regulations and, in any case, which cannot be
reached by those using the spa.

It is mandatory to comply with this instruction. Any other pro-
cedure is prohibited.

If the building’s electrical system is not able to
guarantee a stabile power supply, it is recommen-
ded to install a voltage stabiliser that suitably di-
mensioned for the required power upstream of the
equipment.

I

The disconnection devices must be installed in the power supply

network according to the installation instructions.

I

The installation of electrical devices and equipment (sockets,

switches, etc.) near the spa must be in compliance with legal stan-
dards and regulations in the country where the spa is installed.

I

For equipotential connection in compliance with specific national

regulations, the installer must use the provided terminal (

EN

60335.2.60

standard) on the electric wiring box (

i

4

), marked by

the symbol

. In particular, equipotential connection must be carried

out for all metal parts surrounding the mini-pool, for example, the wa-
ter and gas pipes and any surrounding metal under-frames etc.

I

The appliance comes equipped with an LED lighting system, in com-

pliance with Regulation

EN 62471:2009.

CAUTION! Before carrying out any maintenance oper-
ation, disconnect the appliance from the power supply
line.

Summary of Contents for alimia

Page 1: ...zione CONSERVARE CON CURA Instructions for preinstallation KEEP CAREFULLY Fiche tecnique de pre installation GARDEZ SOIGNEUSEMENT Vorinstallationsblatt SORGF LTIG AUFBEWAHREN Ficha t cnica de preinsta...

Page 2: ......

Page 3: ...Italiano 10 English 12 Fran ais 15 Deutsch 17 Espa ol 20 23 Alimia Index...

Page 4: ...4 212 216 22 5 8 76 3 5 1 2 Alimia wood Alimia synthetic wood Alimia built in 216 x 216 76 212 16 5 8 5 212 202 65 5 90 76 16 8 5 65 5 90 202 76 212 16 5 8 5 202 65 5 90 1 i cm...

Page 5: ...5 Alimia wood Alimia synthetic wood Alimia built in 2 i...

Page 6: ...6 76 cm 5 8 B B 3 4 1 1 2 2 3 3 i...

Page 7: ...ell impianto size based on table Maximum absorption of the system dimensionner en se rapportant au tableau Absorption maximale de l installation auf der Grundlage der Tabelle maximale Aufnahme der Anl...

Page 8: ...8 12 cm Alimia synthetic wood synthetic wood wood OK 6 i 5 i...

Page 9: ...9 208 cm 5 1 4 3 3 2 2 4 5 7 i 8 i...

Page 10: ...la ghiera in senso antiora rio e tirarla nel caso quindi si decida di collegare in modo fisso la spa al pozzetto di scarico consigliabile installare una valvola a valle by passando la valvola montata...

Page 11: ...itare il collegamento con la rete elettri ca sulla cassetta elettrica stato montato un pressacavo M32 x 1 5 mm I L installatore dovr rispettare le suddette prescrizioni nonch uti lizzare raccordi stag...

Page 12: ...ges to ensure optimum water fil tering the filtering surface is equal to 9 3 m2 Maximum absorption of the system The electrical system that powers the spa must absolutely be sized for maximum consumpt...

Page 13: ...eights table provided I You can use a garden hose to fill the spa For periodic filling if you decide to connect the spa hydraulic circuit to the public water system that supplies drinking water this c...

Page 14: ...For electrical connections the installation of a multiple pole sec tion switch is compulsory i4 It must be positioned in a place that complies with safety regulations and in any case which cannot be r...

Page 15: ...teur de la base et en vissant le rac cord avec garniture fournie i3 d tail B NOTE Pour ouvrir la vanne il est n cessaire de tourner la bague dans le sens contraire des aiguilles d une montre et de la...

Page 16: ...s de protection choisis et des normes sp cifiques pour les installations lectriques pose fixe en vigueur dans le pays o est install e la mini piscine spa Le bornier de la bo te lectrique est pr vu pou...

Page 17: ...vorgenommenen Installation Technische Merkmale Im Whirlpool spa Mod Alimia i1 i 2 ist mit zwei Pumpen f r die Wassermassage mit jeweils 2 PS und einer Umlaufpumpe ausgestat tet Zur Gew hrleistung ein...

Page 18: ...mtliche Wartungsarbeiten durchgef hrt werden k nnen Detail 2 Dieser Kanal kann durch entfernbare Trittbretter abge deckt werden Detail 3 die ihrerseits auf entsprechenden Ab st tzungen lagern Detail...

Page 19: ...m Grund permanent ohne Zwischenverbindungen an das Stromversorgungsnetz und an die Erdungsanlage anzuschlie en Die elektrische Anlage der R umlichkeit ist mit ei nem Differentialschalter 0 03 A und ei...

Page 20: ...o i3 det B NOTA para abrir la v lvula se debe girar el anillo en sentido con trario al de las agujas del reloj y tirar de l en caso de que deci da conectar de manera fija la spa al colector de desag e...

Page 21: ...icas estables vigentes en el pa s donde se va a instalar la spa La bornera de la caja el ctrica est predispuesta para cables de secci n de hasta 6 mm2 I Para garantizar el grado de protecci n contra l...

Page 22: ...osiciones de ley y las normas vigentes en el pa s donde se ins tala la spa I Para la conexi n equipotencial prevista por las normas nacionales es pec ficas el instalador deber utilizar el borne previs...

Page 23: ...zi Europe S p A v spa Alimia i 1 i 2 2 2 1 2 9 3 2 spa 3 6 1 I I I I Alimia i1 1 i3 B I spa i3 B spa I Alimia i5 spa i6 spa i1 a i7 8 1 80 2 290 1370 1650 1940 2 2 3 10 626 50 60 x 26 5 75 k k 230 x j...

Page 24: ...spa spa I spa A limia I spa spa EN 1717 AA AB AD I spa Jacuzzi Europe I I 220 240 1 380 415 2N 380 415 3N I 220 240 I 220 240 I 220 240 V 1N min 4 mm2 380 415V3N min 2 5mm2 H 05 VV F spa 6 2 I M32 x 1...

Page 25: ...25 Alimia EN 60335 2 60 EN 61000 EN 55014 I I spa I 0 03 TE ST I i4 spa I I spa spa I EN 60335 2 60 i4 I EN 62471 2009...

Page 26: ......

Page 27: ......

Page 28: ...irezione e Coordinamento Jacuzzi Brands Corp USA S S Pontebbana km 97 200 33098 Valvasone PN ITALIA Tel 39 0434 859111 Fax 39 0434 85278 www jacuzzi eu info jacuzzi it Jacuzzi Spa Bath Ltd Woodlands R...

Reviews: