background image

I. Subnormal voltage.

J. Locked shaft or impeller.
K. Motor windings burned out.
L. Defective starting switch
     inside motor.

11. Motor stops.

A. Motor overload condition.

B. Selector switch failure.
C. Relay failure.
D. Inadequate supply wiring.

E. High temperature safety
     switch tripped.

12. Air Blower does not operate.

A. Power off.

B. ACC switch in OFF.
C. House circuit breaker
     tripped, no power to
     system.
D. Redwood skirt door open
     or not in place.
E. GFCI tripped.
F. Faulty motor.

*Note:  The skills and tools necessary for the safe repair of this spa require the services
             of qualified service personnel.  Contact your Jacuzzi Whirlpool Bath dealer.

I. Call an electrition or your
    power company.
J.  *
K. *

L. *

A. Let cool for one hour.
     Motor overload will reset;
     if problem persists, see *Note.
B. *
C. *
D. Consult electrician to cor-
     rect wiring to unit.
E. Reset button on heater after
    water has cooled; see *Note
    if switch continues to trip.

A. Turn on power at service
     panel.
B. Select other function.
C. Reset circuit breaker.

D. Close redwood skirt
     door.
E. Reset GFCI.

F. *

10. Motor will not start. (Continued)

TROUBLESHOOTING GUIDE

PROBABLE CAUSE

PROBLEM

REMEDY

20

The Palio II™ Portable Whirlpool Spa requires a 115

VAC 20 AMP capacity electrical supply.  If the wiring of the
circuit in which your spa is connected is not sized properly
for 20 AMPs, or if the outlet used is too distant from the main
service panel,  there may be a considerable voltage drop.
Such a voltage drop would not only cause the unit to
malfunction, but it may also cause permanent damage to
the spa's electrical system.

Before operating your spa, therefore, we recommend

that you test the spa's intended electrical supply circuit for
sufficient voltage.  To do this,  you will need as AC voltage
meter and a small electrical appliance rated at 1200 (min.)
- 1600 (max.) watts, such as a toaster or small heater.  With
the appliance turned off, plug it into the receptacle and take
a voltage meter reading from the adjacent receptacle.  Next
turn on the appliance to its maximum setting and again
measure the voltage as before.   The difference between
the two voltage readings must not be more than 5%.  For
example, if the "OFF" voltage is 115, the "ON" voltage must
not be below 109.  If there is a voltage drop of more than 5%
or if there is less than the 105 V minimum operating voltage
at the receptacle, the electrical supply is insufficient.  The
minimum voltage must be maintained during spa operation.

If your test reveals insufficient electrical supply, several

solutions are possible;  First, you could have your electrical
supply upgraded and provide a dedicated, properly wired
circuit with 20 AMP capability to be used for the spa only.
Second,  you can install a transformer which would boost
your existing power supply.  We recommend that you seek
the advice and services of a qualified electrician who can
determine your particular electrical needs for installation of
your spa.

IMPORTANT

20 AMP RECEPTACLE

1200-1600 WATT (MAX.)
APPLIANCE

Summary of Contents for Aero Plus C460000

Page 1: ...PortableWhirlpoolSpa Owner sManual WHIRLPOOL BATH R THEAEROPLUS...

Page 2: ...cle See details in Installation Instructions This unit is provided with a ground fault circuit interrupter GFCI located in the System Control Module Check to be sure this is operational at least once...

Page 3: ..._________________________________________ 12 Silent Air Induction _________________________________________________ 12 Filtration _________________________________________________________ 12 Maintenan...

Page 4: ...Rain bow spout with flow control which will create a dazzling shimmering waterfall effect while recirculating the water The shell is foam insulated to save energy costs and is tastefully surrounded by...

Page 5: ...ol Bath 800 225 8292 for Warranty Service California residents call 415 938 7070 Note Damage or defects which could have been discovered and repaired prior to installation and which are claimed after...

Page 6: ...malfunction may cause fatal shock To increase the heating capacity of your spa s heater and convert the heater output from 1 5 kW to 6 0 kW your spa can be hard wired on site in approved conduit to op...

Page 7: ...oys telephones stereo speakers lights or cooking devices within 5 ft of the spa when the spa is being used 5 All fixed metal objects located within 5 ft of the spa such as fence posts railings door fr...

Page 8: ...r it to rest on To do this construct forms for a 8 x 8 x 4 thick level pad Install a 10gaugewiremesh6 x6 steelreinforcedgrid Attach a 8 solid copper wire to the grid with a ground clamp This wire shou...

Page 9: ...lter frame Plug the line cord into the proper receptacle in a 115 VAC 20 Amp circuit Select JETS on the SYSTEM switch Add 1 4 cup sodium dichlor a fast dissolving granular type of chlorine to the wate...

Page 10: ...OOR SEAL OPENING DOOR VOIDS WARRANTY THIS EQUIPMENT REQUIRES QUALIFIED SERVICE PERSONNEL FOR PROPER REPAIR CONTACT YOUR JACUZZI WHIRLPOOL BATH DEALER FOR SERVICE NO USER SERVICABLE PARTS BEHIND THIS D...

Page 11: ...shut down the spa if the water becomes excessively hot If for some reason the switch is tripped the reset button must be pushed in for the heater to operate again after the water has cooled to about 9...

Page 12: ...ation The other switch ACC Accessory controls the air blower and optional light RefertotheControlPanelillustrationforanexplana tion of the various switch functions SYSTEM The SYSTEM switch controls th...

Page 13: ...l be deter mined by the temperature of the water before turning on the heater For example if the water in the spa is kept OPERATION at about 70 when the spa is not in use and the desired temperature i...

Page 14: ...ol panels For maximum air induc tion rotate each control knob fully counter clockwise to the largest circle For fewer air bubbles decrease the amount of air induction by rotating the control knob cloc...

Page 15: ...soaps or oils or other fatty substances to the spa water The interaction of these with hot water especially at high pH more alkali will cause the water to foam See Water Quality Definitions Oil Film o...

Page 16: ...pm and 150 ppm If the chemistry of the water is not within this range you will have difficulty adjusting your pH level which will affect your adjust ments for the proper amount of free available chlo...

Page 17: ...quality chemicals body oils perfumes dirty feet and winds etc accumulate in the spa and cannot be filtered out it is necessary to drain your spa and refill it with fresh water This should be done ever...

Page 18: ...e 1 Select the HTR FILTER mode 2 Set the thermostat to its minimum temperature 45 50 F by turning the dial all the way counter clock wise 3 Maintain a chemical balance See Water Quality section 4 Keep...

Page 19: ...he spa surface This may be applied to the acrylic surface with a soft cloth and wiped clean Use sparingly in small amounts to avoid contaminating the spa water If heavily soiled it may be advisable to...

Page 20: ...skimmer filter frame C Fill to middle of skimmer D Clean strainers or skimmer baskets E Clean or replace A Wait 60 seconds system will be restored automatically A Relay malfunction B Element malfuncti...

Page 21: ...Locate and repair leaks C Tighten fasteners D Add water to normal water level E F G 9 Water leakage at pump shaft rotating connection between pump and motor A Worn or damaged pump seal A A Plug in uni...

Page 22: ...e may be a considerable voltage drop Such a voltage drop would not only cause the unit to malfunction but it may also cause permanent damage to the spa s electrical system Before operating your spa th...

Page 23: ...rculating system of the spa To make the connections necessary to use the Water Rainbow as a fill spout follow this procedure Make sure spa is unplugged and completely drained Unscrew the spout from th...

Page 24: ...product Jacuzzi Whirlpool Bath makes no representation or warranty regarding and will not be responsible for any code compliance PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE USE INSTAL...

Reviews: