PROBLEM
CAUSES
CORRECTIONS
Leak on the upper portion of
the cylinder.
Worn or dried out piston
cup.
Replace or lubricate
the piston cup.
After pumping and pressuri-
zing the chamber the pumping
lever falls.
Cylinder valve not sealing
properly due to wear or
impurities.
Clean or replace the
valve.
After pumping and pressuri-
zing the chamber, the lever
rises slowly when released.
Chamber valve not sealing
properly due to wear or
impurities.
Clean or replace the
chamber.
Put about 0.5 gallon of water in the tank.
While operating the pumping lever, look
into the tank.
Refer to the table and diagram below.
Put 1 gallon of water in a bucket and
add the chemical product. Stir until it
becomes an homogeneous mixture and
pour the solution into the tank while
filling with water.
Carefully read the chemicals manufac-
turer's label.
Use of individual protective clothing and
safety equipment is recommended.
Do not eat, drink or smoke while spray-
ing.
Do not pollute the environment.
Keep all products out of reach of chil-
dren and animals. Lock up the chemical
products to prevent untrained persons to
handling them.
After finishing the spray application, take
a shower with plenty of water and soap.
Put on clean clothes.
A
B
C
D
> Cylinder maintenance
Remove the pumping rod from the
chamber. Loosen the gasket holder and
remove the assembly.
Remove the chamber
(A)
from the cylin-
der
(B)
. Clean the ball (C) and the piston
cup (D); replace them if necessary.
ATTENTION!
Read carefully the chemicals manufacturer´s labels.
Wash hands and other parts of the body that have touched chemi-
cals before starting to spray.