12/29
5.1. Using the equipment
Follow the steps below to operate your equipment correctly:
• Remove the tank lid.
• Insert the strainer and pour the product to be used in the application.
• Remove the strainer and close the tank lid correctly to avoid waste.
• To apply:
1.
Open the handles of the spreader.
2.
Insert the spreader in the desired location (up to 8 cm deep).
3.
And close the handles, so the dosage is released.
• Repeat these steps until the end of the application.
6. Important information for users
6.1. Cleaning and Maintenance
Keep your equipment in good condition at all times. A well-maintained device is
efficient and easy to operate. Due to contact with various granules, cleaning the
equipment after every use is necessary. To do so, follow the steps below:
• Unscrew the articulation lock screw.
articulation lock
screw
inner
scrapper
seal
cover
dosage regulating
cylinder
1)
2)
3)
• On the other side, unscrew the cover screws.
• And remove the seal, the inner felt, the seal body, and the dosage regulating
cylinder.
• To remove the delivery tube, remove the cotter pin and then remove it, as
shown below.
ATTENTION!
When handling the spreader, wear personal protective
equipment (PPE), such as boots, gloves, protective
glasses, and a face mask.
cotter pin
delivery tube
• Clean all components that had contact with the applied product using a clean
cloth. Do not use any solvent.
• Replace damaged or worn parts.