7
Page Created: 03-24-2011
Revised: 03-11-2013
WAREFORCE UH/UL 30 Technical Manual (07610-003-67-21)
Notes Regarding Electrical Requirements
All electrical ratings provided in this manual are for reference only. Always refer to the machine data plate
to get the exact electrical information for your machine. All electrical work performed on machines should
be done in accordance with applicable local, state, territorial and national codes. Work should only be per-
formed by qualified electricians and authorized service agents. A list of Jackson Authorized Service Agencies
is located in the back of this manual.
Note that all electrical wiring used in the Wareforce UH/UL30 series of machines must be rated, at a mini-
mum, for 100C (212F). Furthermore, use copper conductors only.
Where applicable, heating element amperage draws have been adjusted for the assumed input voltage. Jack-
son assumes incoming voltages will be either 208, 230 or 460 volts. Some of the heating elements used in
our machines are actually rated for other voltages, such as 240 or 480 volts. Always verify the amperage
draw of the machine in operation when sizing circuit protection.
If your machine is equipped with the optional rinse heater, note the rinse heater has its own electrical con-
nection and therefore requires a separate service. Amperage loads for motors and heaters are called out on
the machine data plate for the installation/service technician.
The electrical configurations of the Wareforce UH/UL30 series of machines are as follows:
Available Electrical Characteristics:
115 volt, 60 Hz, single phase
208 volt, 60 Hz, single phase
230 volt, 60 Hz, single phase
460 volt, 60 Hz, three phase
Available Wash Tank Heaters:
8.2KW (standard for WAREFORCE™ UH 30)