07610-003-61-42-T
77
SERIAL NUMBER:
MODEL: Tempstar
Made in the USA
Jackson WWS, Inc.
P.O. Box 1060
Barbourville, KY. 40906
(606) 523-9795
09905-003-69-11D
460V
WASH MOTOR
230V
208V
3/4 HP
5.7 A
3/4 HP
5.7 A
3/4 HP
1.8 A
WASH HEATER
4.1 KW
11.4 A
5 KW
12.6 A
5 KW
6.3 A
RINSE HEATER
9 KW
25.0 A
11 KW 27.2 A
11 KW 13.8 A
TOTAL LOAD
42.1 A
45.5 A
21.9 A
40 F RISE BOOSTER
460V
WASH MOTOR
230V
208V
3/4 HP
5.7 A
3/4 HP
5.7 A
3/4 HP
1.8 A
WASH HEATER
4.1 KW
11.4 A
5 KW
12.6 A
5 KW
6.3 A
RINSE HEATER
10.5 KW 29.1 A
12.9 KW 32.4 A 12.9 KW 16.2 A
TOTAL LOAD
46.2 A
50.7 A
OPERATING PARAMETERS
MINIMUM WASH TEMPERATURE
150 F
MINIMUM RINSE TEMPERATURE
180 F
MINIMUM INCOMING WATER TEMPERATURE
70 F RISE BOOSTER
110 F
40 F RISE BOOSTER
140 F
WASH CYCLE TIME
45 SEC
RINSE CYCLE TIME
11 SEC
FLOW PRESSURE
10 PSI
208-230-460 Volt/60 Hz/3 Phase
WASH MOTOR
230V
208V
3/4 HP
5.7 A
3/4 HP
5.7 A
WASH HEATER
4.1 KW
19.7 A
5 KW
21.7 A
RINSE HEATER
9 KW
43.3 A
11 KW 47.8 A
TOTAL LOAD
68.7 A
75.2 A
40 F RISE BOOSTER
WASH MOTOR
230V
208V
3/4 HP
5.7 A
3/4 HP
5.7 A
WASH HEATER
4.1 KW
19.7 A
5 KW
21.7 A
RINSE HEATER
10.5 KW 50.4 A
12.9 KW 56.1 A
TOTAL LOAD
75.8 A
83.6 A
70 F RISE BOOSTER
208-230 Volt/60 Hz/1 Phase
24.3 A
70 F RISE BOOSTER
4000897
Conforms to UL Std 921
Conforms to CSA
Std C22.2 No.168
Intertek
Jackson Technical
Manual Addendum
Tempstar units that are manufactured with the above referenced data plate are able to be fi eld-
converted to different phases and voltages. To accomplish this, your unit should have shipped
with the Tempstar Phase Conversion Kit, part number 06401-003-71-71. This kit contains the
appropriate decals and schematics to apply to your unit once the conversion is complete.
All work should be performed only by Authorized Jackson Service Agents.
Steps:
1. Perform the appropriate wiring and component changes as necessary to achieve
the desired result. Reference Jackson technical manuals or contact technical service for
assistance.
2. Verify the Schematic is correct. If not, replace with the correct one from the kit.
3. At the power inlet, remove the “Wired For” decal and replace with the one that matches the
confi guration of your machine.
ADDENDUM
Summary of Contents for TEMPSTAR
Page 2: ......
Page 31: ...24 07610 003 61 42 T TOP CONTROL BOX ASSEMBLY PARTS Continued 26 1 29 28 30 33 34 36 ...
Page 66: ...59 07610 003 61 42 T PARTS TEMPSTAR VENTLESS SYSTEM ASSEMBLY ...
Page 77: ...70 TEMPSTAR 460 V 60 HZ 3 PHASE SCHEMATICS TEMPSTAR TOP MOUNT W CYCLE SWITCHES ...
Page 79: ...72 TEMPSTAR LT NB 208 230V 50 60HZ 1 3 PHASE SCHEMATICS TEMPSTAR TOP MOUNT W CYCLE SWITCHES ...
Page 82: ...75 07610 003 61 42 T SCHEMATICS SDI OPTIONS ...
Page 83: ...76 07610 003 61 42 T DRAIN QUENCH OPTIONS SCHEMATICS ...
Page 85: ......