07610-004-29-29-D
6
ELECTRICAL REQUIREMENTS
SPECIFICATIONS
On three-phase machines, imbalanced wild leg goes to L3
Also see the Motor Rotation section
NOTICE
DYNATEMP & DYNATEMP VER
Local codes may require more stringent protection than what is displayed here. Always verify with your electrical service
contractor that your circuit protection is adequate and meets all applicable national and local codes. Numbers in this manual
are for reference and may change without notice
Volts
Phase
Freq
Wash
Motor
Wash
Heater
Rinse
Heater
Total Load
MCA
MOP
208
1
60 Hz
5.0 A
19.7 A
50.6 A
75.3 A
76.6 A
80.0 A
230
1
60 Hz
5.0 A
21.8 A
55.9 A
82.7 A
84.0 A
90.0 A
208
3
60 Hz
5.0 A
11.4 A
29.2 A
45.6 A
46.9 A
50.0 A
230
3
60 Hz
5.0 A
12.6 A
32.3 A
49.9 A
51.2 A
55.0 A
460
3
60 Hz
1.8 A
6.3 A
16.1 A
24.2 A
24.7 A
30.0 A
i
DYNATEMP NB
Volts
Phase
Freq
Wash
Motor
Wash
Heater
Rinse
Heater
Total Load
MCA
MOP
208
1
60 Hz
5.0 A
19.7 A
N/A
24.7 A
26.0 A
30.0 A
230
1
60 Hz
5.0 A
21.8 A
N/A
26.8 A
28.1 A
30.0 A
208
3
60 Hz
5.0 A
11.4 A
N/A
16.4 A
17.7 A
20.0 A
230
3
60 Hz
5.0 A
12.6 A
N/A
17.6 A
18.9 A
20.0 A
460
3
60 Hz
1.8 A
6.3 A
N/A
8.1 A
8.6 A
15.0 A
DYNATEMP S
Volts
Phase
Freq
Wash
Motor
Wash
Heater
Rinse
Heater
Total Load
MCA
MOP
208
1
60 Hz
5.0 A
N/A
N/A
5.0 A
6.3 A
15.0 A
230
1
60 Hz
5.0 A
N/A
N/A
5.0 A
6.3 A
15.0 A
208
3
60 Hz
5.0 A
N/A
N/A
5.0 A
6.3 A
15.0 A
230
3
60 Hz
5.0 A
N/A
N/A
5.0 A
6.3 A
15.0 A
460
3
60 Hz
1.8 A
N/A
N/A
1.8 A
2.3 A
15.0 A
Summary of Contents for Dynatemp Series
Page 2: ......
Page 39: ...07610 004 29 29 D 32 11 10 9 12 13 19 20 4 18 17 16 14 15 1 2 3 5 6 7 8 21 TUB PARTS ...
Page 41: ...07610 004 29 29 D 34 11 10 13 18 19 4 17 16 15 1 2 3 5 7 8 6 12 14 9 STEAM TUB PARTS ...
Page 45: ...07610 004 29 29 D 38 PARTS WASH RINSE ARMS 1 2 3 4 5 6 7 8 9 10 11 ...
Page 67: ......