12
07610-003-78-18-N
Volts
Phase
Freq
Pre-Wash
Motor
Amps
Wash
Motor
Amps
Drive
Motor
Amps
Wash
Heater
Amps
Total
Load
208
1
60
10.2
10.0
1.8
86.5
108.5
230
1
60
9.4
10.0
1.8
*71.9
93.1
240
1
60
9.4
10.0
1.8
75.0
96.2
208
3
60
6.8
8.6
1.1
50.0
66.5
230
3
60
6.4
8.4
1.1
*41.5
57.47
240
3
60
6.4
8.4
1.1
43.4
59.3
460
3
60
3.2
4.2
0.6
**20.8
28.8
480
3
60
3.2
4.2
0.6
21.7
29.7
66" with 18 kW Wash Heater
Volts
Phase
Freq
Pre-Wash
Motor
Amps
Wash
Motor
Amps
Drive
Motor
Amps
Total
Load
208
1
60
10.2
10.0
1.8
22.0
230
1
60
9.4
10.0
1.8
21.2
208
3
60
6.8
8.6
1.1
16.5
230
3
60
6.4
8.4
1.1
15.9
460
3
60
3.2
4.2
0.6
8.0
66" Steam
* Denotes 240 volt heating elements that have been down-rated when 230 volts is applied.
** Denotes 480 volt heating elements that have been down-rated when 460 volts is applied.
Volts
Phase
Freq
Rinse
Heater
Amps
208
1
60
57.7
230
1
60
47.9
208
3
60
33.3
230
3
60
27.7
460
3
60
13.8
40
°
F Rise – 12 kW Booster
Volts
Phase
Freq
Rinse
Heater
Amps
208
1
60
82.7
230
1
60
71.9
208
3
60
47.7
230
3
60
41.5
460
3
60
20.7
70
°
F Rise – 18 kW Booster
Note: On the 208 volt machines, the rinse heater is actually rated at 17.2 kW.
Volts
Phase
Freq
Amps
208
3
60
32.2
230
3
60
22.9
460
3
60
13.4
Blower/Dryer
ELECTRICAL REQUIREMENTS
SPECIFICATIONS
i
Summary of Contents for crew series
Page 2: ......
Page 6: ......
Page 81: ...72 07610 003 78 18 N STEAM BOOSTER HEATER SCHEMATICS...
Page 84: ...75 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 44 ELECTRICALLY HEATED SCHEMATICS...
Page 85: ...76 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 44 ELECTRICALLY HEATED SCHEMATICS...
Page 86: ...77 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 44 STEAM HEATED SCHEMATICS...
Page 87: ...78 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 44 STEAM HEATED SCHEMATICS...
Page 88: ...79 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 66 ELECTRICALLY HEATED SCHEMATICS...
Page 89: ...80 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 66 ELECTRICALLY HEATED SCHEMATICS...
Page 90: ...81 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 66 STEAM HEATED SCHEMATICS...
Page 91: ...82 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 66 STEAM HEATED SCHEMATICS...
Page 92: ...83 07610 003 78 18 N BLOWER DRYER 240V SCHEMATICS...
Page 93: ...84 07610 003 78 18 N BLOWER DRYER 480V SCHEMATICS...