25
07610-003-78-18-N
1
2
3
4
5
6
7
8
INPUTS
1
2
3
4
5
6
7
8
OUTPUTS
PWR
RUN
OK
PLC1
LIGHT CONFIGURATION
INPUTS:
1. ON/OFF BUTTON
2. DOOR SWITCH SAFETY INTERLOCKS
3. RACK INLET SWITCH
4. FINAL RINSE SWITCH
5. LOWER WASH FLOAT SWITCH
6. UPPER WASH FLOAT SWITCH
7. MANUAL / DELIME SWITCH
8. SPARE
OUTPUTS:
1. FINAL RINSE SOLENOID / RINSE SIGNAL RELAY
2. WASH TANK FILL SOLENOID
3. DRIVE MOTOR CONTACTOR
4. WASH MOTOR CONTACTOR
5. WASH HEATER CONTACTOR or
STEAM HEAT RELAY (Steam Units Only)
6. VENT FAN RELAY
7. N/A
8. N/A
1
2
3
4
5
6
7
8
INPUTS
1
2
3
4
5
6
7
8
OUTPUTS
PWR
RUN
OK
PLC2
LIGHT CONFIGURATION
INPUTS:
1. LOWER PRE-WASH FLOAT SWITCH (66 UNITS ONLY)
2. UPPER PRE-WASH FLOAT SWITCH (66 UNITS ONLY)
3. NOT USED
4. NOT USED
5. NOT USED
6. NOT USED
7. NOT USED
8. NOT USED
OUTPUTS:
1. PRE-WASH TANK FILL SOLENOID
2. PRE-WASH MOTOR CONTACTOR
3. NOT USED
4. NOT USED
5. NOT USED
6. NOT USED
7. N/A
8. N/A
INPUTS:
1. On/Off Switch
2. Door Switch Safety Interlocks
3. Rack Inlet Switch
4. Final Rinse Switch
5. Lower Wash Float Switch
6. Upper Wash Float Switch
7. Manual/Delime Switch
8. Side-Loader Switch (on with no rack present)
OUTPUTS:
1. Rinse Solenoid/Rinse Signal Relay
2. Wash Tank Fill Solenoid
3. Drive Motor Contactor
4. Wash Motor Contactor
5. Wash Heater Contactor or Steam Heat Relay
6. Ventilation Fan Relay
7. N/A
8. N/A
INPUTS:
1. Lower Pre-Wash Float Switch (66 Units Only)
2. Upper Pre-Wash Float Switch (66 Units Only)
3. N/A
4. N/A
5. N/A
6. N/A
7. N/A
8. N/A
OUTPUTS:
1. Pre-Wash Tank Fill Solenoid (66 Units Only)
2. Pre-Wash Motor Contactor (66 Units Only)
3. N/A
4. N/A
5. N/A
6. N/A
7. N/A
8. N/A
MAINTENANCE
TROUBLESHOOTING
Summary of Contents for CREW 44
Page 2: ......
Page 6: ......
Page 81: ...72 07610 003 78 18 N STEAM BOOSTER HEATER SCHEMATICS ...
Page 84: ...75 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 44 ELECTRICALLY HEATED SCHEMATICS ...
Page 85: ...76 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 44 ELECTRICALLY HEATED SCHEMATICS ...
Page 86: ...77 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 44 STEAM HEATED SCHEMATICS ...
Page 87: ...78 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 44 STEAM HEATED SCHEMATICS ...
Page 88: ...79 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 66 ELECTRICALLY HEATED SCHEMATICS ...
Page 89: ...80 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 66 ELECTRICALLY HEATED SCHEMATICS ...
Page 90: ...81 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 66 STEAM HEATED SCHEMATICS ...
Page 91: ...82 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 66 STEAM HEATED SCHEMATICS ...
Page 92: ...83 07610 003 78 18 N BLOWER DRYER 240V SCHEMATICS ...
Page 93: ...84 07610 003 78 18 N BLOWER DRYER 480V SCHEMATICS ...