18
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
CAM TIMER OPERATION FOR LT-3 (CONTINUED)
CAM 6: Cam 6 is an adjustable cam and controls the sanitizer pump.
FUNCTION: The sanitizer pump cam works off the normally closed contacts of cam 6. This requires the switch to be held open
by the cam and allowed to drop into the notch to operate the pump.
SETTINGS: The left side of cam 6 must be set to drop in just past the starting point of the wash cam. The adjustment for san-
itizer volume must be made with the right side of the cam.
CAM 7: Cam 7 is an adjustable cam and controls the detergent pump.
FUNCTION: The detergent pump cam works off the normally closed contacts of cam 7. This requires the switch to be held open
by the cam and allowed to drop into the notch to operate the pump.
SETTINGS: The left side of cam 7 must be set to drop in just past the starting point of the wash cam. The adjustment for deter-
gent volume must be made with the right side of the cam.
CAM 8: Cam 8 is an adjustable cam and controls the rinse aid pump.
FUNCTION: The rinse aid pump cam works off the normally closed contacts of cam 8. This requires the switch to be held open
by the cam and allowed to drop into the notch to operate the pump.
SETTINGS: The left side of cam 8 must be set to drop in just past the starting point of the wash cam. The adjustment for rinse
aid volume must be made with the right side of the cam.
Summary of Contents for Chemical Dispensing Unit HT-1
Page 2: ......
Page 6: ...1 SECTION 1 SPECIFICATION INFORMATION ...
Page 7: ...2 SECTION 1 SPECIFICATION INFORMATION DIMENSIONS ...
Page 8: ...3 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...
Page 24: ...19 SECTION 3 PARTS SECTION ...
Page 25: ...20 SECTION 3 PARTS SECTION HT 1 ASSEMBLY 4 3 1 7 2 10 13 5 6 14 12 11 15 16 17 9 10 8 18 ...
Page 30: ...4 3 1 7 2 10 13 5 6 14 12 11 15 16 17 9 10 8 18 25 SECTION 3 PARTS SECTION LT 1 ASSEMBLY ...
Page 35: ...30 SECTION 4 ELECTRICAL SCHEMATICS ...
Page 37: ...32 SECTION 4 ELECTRICAL DIAGRAMS HT 2 115 VOLT 60 HERTZ SINGLE PHASE ...
Page 38: ...33 SECTION 4 ELECTRICAL DIAGRAMS HT 2 208 240 VOLT 60 HERTZ SINGLE PHASE ...
Page 39: ...34 SECTION 4 ELECTRICAL DIAGRAMS LT 1 115 VOLT 60 HERTZ SINGLE PHASE ...
Page 40: ...35 SECTION 4 ELECTRICAL DIAGRAMS LT 3 115 VOLT 60 HERTZ SINGLE PHASE ...
Page 41: ...36 SECTION 4 ELECTRICAL DIAGRAMS LT 3 240 VOLT 60 HERTZ SINGLE PHASE ...
Page 42: ...37 SECTION 5 JACKSON MAINTENANCE REPAIR CENTERS ...