07610-003-60-98-L
11
SPECIFICATIONS
MACHINE DIMENSIONS
AJX-80 RIGHT-TO-LEFT
Front
44 [1118 mm]
Base Unit
B
7 [178 mm]
88 [2238 mm]
98 [2489 mm] Overall
80 [2035 mm] Table-to-Table
N
P
D
E
8 [203 mm]
36 [914 mm]
Pre-wash
24 [609 mm]
23 [598 mm]
21 [533mm]
N
P
B
Machine
Drain Line
1 1/2 [38 mm]
MIN, Must NOT
Be Reduced.
Pitch 1/4
[6 mm] per ft.
Must Install
Machine Drain
Line above
3 [76 mm] MIN
Floor Drain
or Sink
1 1/2
[38 mm]
MIN
Air-gap
14 [355 mm] MIN
4 [102 mm] x 16 [406 mm]
Cut-out in Vent Cowl/Splash Shield.
Shipped with Cover Plate.
Scrap Trough
4 [102 mm] MIN
5 [127 mm]
Top
A
40 [1016 mm]
7 [178 mm]
DRIVE KEY
STROKE
8 [203 mm]
F
12
1
2
[316 mm]
LEGEND
A - Water Inlet
(3/4" NPT, 110–140 °F MIN)
B - Electrical Connection
C - Drain Connection
(1 1/2" NPT)
D - Vent Collar - Optional
E - Vent Cowl - Standard
F - Machine Steam Inlet
(3/4" NPT)
G - Condensate Return
(3/4" NPT)
H - Steam Booster Electrical Connection
(7/8" Hole)
J - Booster Steam Inlet
(1" NPT)
K - Condensate Connection
(3/4" NPT)
L - Water Inlet for Booster (from Facility)
(3/4" NPT, 110 °F)
M - Water Outlet to Machine
(3/4" NPT, 180 °F)
N - Pre-wash Water Inlet
(3/4" NPT, 110–140 °F)
P - Cold Water Thermostat - Optional
(3/4" NPT)
All dimensions from the floor can be
increased 1” using the machine’s
adjustable feet.
Items in red are not supplied
with the machine.
Items in blue are for the Steam option.
DRIVE
UNIT
75
1
2
[1915 mm]
62
1
2
[1588 mm]
29 [737 mm]
60 [1530 mm]
F
1712
[442 mm]
10 [254 mm]
4 [102 mm]
41 [1041 mm]
A
6 [165 mm]
C
48 [1219 mm]
1
2
9 [238 mm]
3
8
1
4
1
2
34 [864 mm]
21 [533 mm]
25 [635 mm]
12 [307 mm]
25 [635 mm]
1
2
[15 mm]
84 [2134 mm]
CLEARANCE
Left
Right
66 [1692 mm]
65 [1665 mm]
A
B
C
DOOR OPEN
31 [787 mm]
M
J
K
H
3318
[841 mm]
20 34
[527 mm]
14 58
[372 mm]
278
[76 mm]
20 18
[511 mm]
22
[559 mm]
338
[86 mm]
1138
[289 mm]
J
L
M
3311
16
[856 mm]
20 14
[514 mm]
Front
Top
Steam Booster
DRIVE
UNIT
1
2
1
2
6 [152 mm]
G
7 [191 mm]
1
2
Summary of Contents for AJX SERIES
Page 91: ...07610 003 60 98 L 83 SCHEMATICS AJX 44 54CE 208 230 V 50 60 HZ 1 PHASE...
Page 92: ...84 07610 003 60 98 L SCHEMATICS AJX 44 54CE 460 V 50 60 HZ 3 PHASE...
Page 93: ...07610 003 60 98 L 85 SCHEMATICS AJX 44 54CS 208 230 V 50 60 HZ 1 PHASE...
Page 94: ...86 07610 003 60 98 L SCHEMATICS AJX 44 54CS 460 V 50 60 HZ 3 PHASE...
Page 95: ...07610 003 60 98 L 87 SCHEMATICS AJX 66 76 80 90CE 208 230 V 50 60 HZ 1 PHASE...
Page 96: ...88 07610 003 60 98 L SCHEMATICS AJX 66 76 80 90CE 460 V 50 60 HZ 3 PHASE...
Page 97: ...07610 003 60 98 L 89 SCHEMATICS AJX 66 76 80 90CS 208 230 V 50 60 HZ 1 PHASE...
Page 98: ...90 07610 003 60 98 L SCHEMATICS AJX 66 76 80 90CS 460 V 50 60 HZ 3 PHASE...
Page 99: ...07610 003 60 98 L 91 SCHEMATICS SIDE LOADER...
Page 101: ......