background image

Z-200-HC Installation and Operation Instructions

Typical System Layout

ZONE DAMPER 2

MIGHT SERVE

BEDROOM AREA

ZONE DAMPER 1

MIGHT SERVE

LIVING AREA

ZONE 1

STAT

ZONE 2

STAT

Z-200-HC

PANEL

24 VOLT 40VA

TRANSFORMER

FURNACE

HIGH/LOW

LIMIT

SENSOR

Zone Control Made Simple™

5418 Elmwood Avenue, Indianapolis, IN 46203-6025
Toll Free: 888.652.9663 Fax: 317.227.1034
www.jacksonsystems.com

06-1024-020608

Specifications:

Terminal Designations:

Panel Dimensions:

Mounting:

Operating Temperature Rating:

Operating Humidity:

Wiring:

Time Delays:

Thermostats:

Thermostats:

Dampers:

High / Low Limit

HVAC Equipment:

Panel Power:

Height: 8.0 Inches
Width:

6.0 Inches

Depth:

1.375 Inches

Snap Track with 2 back plate screws

-40° F to 150° F

5% to 90% RH non-condensing

18-gauge wire for all equipment

and system connections

3 minutes minimum off between cooling calls
3 minutes minimum off on low limit
20 minute time share

Single-stage heat / cool thermostats
Programmable or non-programmable
Auto or manual changeover

C

24Vac (Common)

R

24Vac (Hot)

W

Heat

Y

Cool

G

Fan

D

Powered Closed / Spring Open (2 wire)

DAS

Discharge Air Sensor (2 wire)

R

24Vac (Hot)

W

Heat

Y

Cool

G

Fan

X

24Vac (Common)

H

24Vac (Hot)

System Checkout:

1. Verify that all component wires have been connected to
the proper terminals and are secure.
2. Disconnect the HVAC ‘R’ terminal wire at the panel and
apply 24Vac to the panel.
3. Confirm that the LIMIT LED is ON.
4. Place both zone thermostats in the OFF position.
5. Put zone #1 thermostat in the heating mode and have
the thermostat call for heat. Confirm that (ZD1) LED is ON
and that (W) LED is ON. Confirm that zone #1 damper is
open and zone #2 damper is closed. There will be no
voltage on zone #1 ‘D’ and ‘D’ terminals and 24Vac on zone
#2 ‘D’ and ‘D’ terminals.
6. Put zone #1 thermostat in the cooling mode and have
the thermostat call for cooling. Confirm that (ZD1) LED is
ON and that the (Y) and (G) LEDs are ON. The cooling call
may not activate immediately due to thermostat or panel
cooling time delays.
7. Turn zone #1 thermostat off and repeat steps 5 and 6
with zone #2 thermostat. Remember, the zone calling will
have its damper open and there will be no 24Vac on the ‘D’
and ‘D’ terminals for that zone.
8. Determine the ventilation mode of each zone thermostat
by setting the thermostats in the Fan Auto or ON mode.
9. Reconnect the HVAC ‘R’ wire at the panel.

Z NE

N

E

E

R

G

E

H

T

Zone Control Made Simple

TM

TM

1 Heat / 1 Cool - Auto Changeover - First Call Priority - Time Share

Reviews: