background image

5418 Elmwood Avenue, Indianapolis, IN 46203-6025
Toll Free:   888.652.9663  Fax:   317.227.1034
www.jacksonsystems.com

06-1071-062011

Setting the Heating Limit

This manual is to be used by the installer only and contains 
information on setting the heating setpoint limit.  Avoid leaving this 
installation manual with anyone who could compromise the settings

.

To set the Heating setpoint limit, place the MODE switch in the OFF 
position. Press and hold the UP button while sliding the MODE switch to 
Heat. The LCD will display “Ht LIM”. Adjust the maximum heating setpoint 
by using the UP and DOWN buttons. 

NOTE: If no buttons are pressed for 4 seconds, the thermostat will accept 
the limit value that is displayed on the LCD and return to normal operation. 

Once  the heating setpoint limit is adjusted and the thermostat returns to 
normal operation, confirm that the setpoint can not be raised above the 
limit and then allow the thermostat to return to normal operation.