8
N
ATURAL
G
AS
C
ONVERSION
Tools required to convert this unit from propane gas to natural gas:
# 2 Phillips screwdriver
8 and 18 mm wrenches
Adjustable wrench
The outdoor gas appliance and its individual shut off
valve must be disconnected from the gas supply
piping system during any pressure testing of that
system at test pressures in excess of ½ psi (3.5 kPa).
1. Remove the lid by twisting the tee handle counter
clockwise until the lid assembly is released from the
body.
2. Remove logs & embers from unit (if already installed).
3. Using a # 2 Philips screwdriver, remove 2 screws
holding the burner in place.
4. Slide back and lift burner out of the fire pit body (see
Figure 11).
5. Using the Philips screwdriver, loosen the screw on the
air shutter located on the burner, turn the shutter so
that it is completely closed. Re-tighten the screw.
Re-install burner in reverse order.
6. Using a 18 mm wrench, remove propane hose
assembly from fire pit body (see Figure 12).
7. Using a 8 mm wrench, remove the brass propane
orifice from the tip that was installed into the fire pit
body. Set it aside, and install the supplied natural gas
orifice. DO NOT OVER TIGHTEN.
8. Remove brass assembly with orifice from the propane
hose, and install into the open end of the rubber flex
hose on the natural gas hose assembly (see Figure
13).
9. Re-install natural gas hose assembly with new NG orifice
into the fire pit. Re-install logs & embers.
REMEMBER TO LEAK CHECK ALL FITTINGS AND ORIFICE AFTER ALL OF THE
CONVERSION IS COMPLETED, LEAK CHECK ALL FITTINGS AND TEST FIRE UNIT TO
ENSURE PROPER, SAFE OPERATION.
Figure 11
Figure 12
Figure 13