Figure 8
Clearance to Combustibles:
A) TOP:
from top of grate to any combustibles* above unit:
5 feet minimum
*Such as decks, ceilings, hanging plants, etc.
B) REAR:
from rear of unit to any combustibles behind unit:
1 inch minimum
C) SIDE:
from the outside edges the unit, to any adjacent combustibles:
1 inch minimum
LEAK TESTING:
STEP 1
Mix a solution of liquid dish soap and water (or obtain profession leak detector liquid).
Turn on Gas.
STEP 2
Spray or brush detector liquid thoroughly on all fuel line connections (Fig. 8). If soap bubbles
are generated at any connection, tighten the fitting and re-test. If a leak is detected that
cannot be successfully repaired, immediately
turn off the gas
and contact your dealer for
further assistance.
LIGHTING INSTRUCTIONS:
1.
Turn the main gas supply ON.
2.
Depress the side burner control knob down slightly and turn
SLOWLY
counter clo
ck wise until the ‘click’ of
the igniter is heard. (This side burner has a built in ignition system).
3.
If the side burner does NOT light, turn the control knob to the OFF position and try again.
4.
Once the burner has lit, turn the control knob counter clock wise to the desired heat level.
NOTE: To turn the unit off, turn the gas control clockwise to the OFF position.
!WARNING!
Please allow extra space when the unit is backed up to vinyl siding;