11
VERY IMPORTANT: DISCONNECT THE TANK WHEN THIS GRILL IS NOT IN USE.
To disconnect L.P. gas tank:
1. Turn all the knobs off.
2. Turn the tank valve off fully (turn clockwise to stop).
3. Detach the regulator assembly from tank valve by turning the quick coupling nut counterclockwise.
4. Install the protective cap back L.P. tank valve.
Tools required to convert this grill from Propane Gas to Natural Gas (tools not provided):
1. # 2 Phillips screwdriver
2. 7 and 9 mm wrenches
The NG conversion kit is supplied with this grill:
Item
Description
Quantity
1
3 pcs
2
1 pc
The outdoor gas appliance and its individual shut off valve must be disconnected from the
gas supply piping system during any pressure testing in excess of ½ psi (3.5 kPa).
The outdoor gas appliance must be isolated from the gas supply by closing its individual
manual shut off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5 kPa).
MAIN BURNER CONVERSION
1. Remove the cooking grids and flame diffusers.
2. Remove the cotter pins that hold the main burners to the firebox rear wall, then remove burners.
3. Using a 7 mm wrench undo all of the main burner orifices from the underside of the control panel.
4. After all the propane orifices are removed from the grill place them in a safe spot away from your
NATURAL GAS CONVERSION
NG Orifice, Main Burner: #53 drill size
NG Orifice, Rotisserie Burner: #53 drill size
Summary of Contents for JENC-LP
Page 6: ...6 EXPLODED VIEW PARTS LIST...