ProTIG 220/300 AC/DC
Operating manual
Page 34
SAVE
23. JOB Menu
It is possible to save up to 7 different welding settings as JOBs.
Store JOB:
Adjust the machine optimally for the welding job.
Press key JOB (item 13) for more than 5 seconds, until the display shows Pr 1.
Now select a disk space between Pr 1 and Pr 7 by rotating the knob (item 9).
An occupied disk space is indicated by lit LEDs, for a free memory locations no LED lights up.
To store the JOB, press key ‚SAVE‘ (item 12) for more than 3 seconds until ‘Sto’ appears in the display.
Now the JOB is stored.
Recall JOB:
To call a stored JOB, Press key JOB (item 13) for more than 5 seconds, until the display shows Pr 1.
Now, using the knob (item 9) select the JOB between Pr 1 and Pr 7 you want to select.
To load the JOB, tap on the key JOB again.
The display shows permanently
the selected JOB e.g. Pr 1.
View Saved parameters
:
To display the stored parameters of the JOB, press the function button (item 4).
All parameters are displayed one after another by tapping the button.
To exit, press and hold the key longer.
Leave JOB:
To change from the JOB mode in the normal manual mode, press the key JOB (item 13) for 5 seconds
until the display shows the current JOB number, eg Pr 1 (Pr 1 is flashing).
Now rotate the knob (item 9) as long as 3 dashes --- appear in the display.
Press the JOB key again, the machine is now in the normal manual mode.
24. Special functions (Expert mode)
With this function, in 2-cycle mode the starting current IS and the final current IE, as well as the
HOTASTART time for electrode mode can be set.
Because these parameters have strong influence on the ignition and welding end, they should be changed
only by qualified personnel.
Change to Expert mode:
• Switch machine OFF
• Press key JOB (item 13) down
• Switch machine ON
• The display shows ‚Std‘, now rotate the knob (item 9) until ‚SPE‘ appears in the display, press key JOB
again.
Now the machine is in Expert mode.
As described in Chapter 4 – functions -, set the parameters:
Start current IS:
5 – 220/300A
End current IE:
5 – 220/300A
Hotstart time t:
t.01 (= 0,01s) to t.50 (=0,5s)
At the end of the settings, the machine must be set back to the default mode.
Change to default mode:
• Switch machine OFF
• Press key JOB (item 13) down
• Switch machine ON
• The display shows ‚SPE‘, now rotate the knob (item 9) until ‚Std‘ appears in the display, press key JOB
again.
Now the machine is in standard mode and can be used normally again.
Summary of Contents for ProTIG 220 DC
Page 44: ...ProTIG 220 300 AC DC Operating manual Page 42 Seitenansichten side view ProTIG 220...
Page 46: ...ProTIG 220 300 AC DC Operating manual Page 44 Seitenansichten side view ProTIG 300...
Page 48: ...ProTIG 220 300 AC DC Operating manual Page 46 34 Ersatzteile Spare parts KG 11...
Page 59: ...ProTIG 220 300 AC DC Operating manual Page 57...