background image

 

 

Plasma 33 H 

 

Operating Manual 

 

Page 6 

5.  Control Elements 

 
Master switch (Front panel) 

Position "O":  unit is switched off. 
Position  "I":   unit is switched on. 

 
Control lamp ‘mains’ (Front panel green) 

is lit when unit is switched on. 
 
 

6.  Initial operation 

 

6.1  Place of installation 

 
The unit should not be exposed to moisture, welding spatter and the direct ray of sparks at 
grinding works. 

 
6.2  Mains connection 

 
Fit a power plug to the mains cable as indicated on the rating plate. The 3 phases (black, 
brown, blue) may be connected to L1, L2, L3 as you like. 
 

4.3  Connecting the compressed air 

 

 
Connect compressed air supply by rapid action hose coupling at the backside of the unit.  
 
The mounted filter pressure reducer regulates the connected comressed air supply to the 
correct  working  pressure.  Pay  attention  to  a  sufficient  pressure  and  a  sufficient  flow 
quantity  of  the  pressure  air  supply.  Besides  the  air  must  be  as  free  as  possible  from  oil 
and water. 
 

Warning!

 

The water tanks must be emptied periodically. 

 

The  water  tank  empties  automatically  itself,  when  the  air  system 
becomes  pressureless.  If  the  machine  is  fixedly  connected  to  a 
compressed air supply being continously under pressure, the machine 
must be separated from the compressed air supply to empty the water 
tank. 

 

4.4  Connecting the torch 

 
The  cutting  torch  is  already  connected  to  the  unit  in  factory.  Both  parts  are  tested  and 
delivered as one unit.

 

If  the  cutting  torch  must  be  exchanged  later  on,  an  expert  must  take  off  the  housing 
bonnet  and  connect  tightly  the  new  torch  at  the  corresponding  connections.  The  blade 
terminals of the torch trip line may be pluged into the trip line socket as you like. 
 

Warning!

  

Pull power-supply plug prior to opening the casing of the plasma unit.

 

 

Summary of Contents for Plasma 33 H

Page 1: ...Plasma Cutting Unit Plasma 33 H...

Page 2: ...ent work with the Plasma 33 H cutting unit Please read the instructions carefully prior to initial operation of the unit The information contained in this manual should be made available to all operat...

Page 3: ...e corresponds to the safety requirements of the recommendations Name of unit Plasma Cutting Unit Type of unit Plasma 33 H Relevant EMC recommendation 89 336 EEC EC recommendations modified by recommen...

Page 4: ...rvice and Maintenance 8 9 Functional description of the control PCB 9 10 Error messages of the control PCB 10 11 Trouble Shooting 11 12 Spare Parts 12 13 Spare parts torch PSB 31 HF S 14 14 Circuit di...

Page 5: ...l from the kerf A clean clear cut is the result 1 2 Advantages Time saving due to high cutting speed in cutting thin sheet metal if compared to oxy fuel gas cutting nibbling or sawing Heat build up is...

Page 6: ...preferably fitted below the cutting zone should be provided The cutting area of the workpiece has to be cleaned and free of solvants and degreasing agents to prevent the formation of toxic gas The use...

Page 7: ...e 449 50939 K ln Furthermore we point out that in some operative ranges where despite the observance of radiation limits this cutting unit can cause electromagnetic interferences which are the respon...

Page 8: ...g as plasma gas and for another as a cooling medium for the torch body to protect against high thermic load HF ignited pilot arc A pilot arc which is initiated by a high frequency spark starter ensure...

Page 9: ...A 92 V Max cutting thickness quality cut 7 mm severance cut 10 mm System of protection IP 23 Insulation class H 180 C Type of cooling F Dimensions L x W x H mm 350x230x350 Weight 30kg Compressed air s...

Page 10: ...ressure Pay attention to a sufficient pressure and a sufficient flow quantity of the pressure air supply Besides the air must be as free as possible from oil and water Warning The water tanks must be...

Page 11: ...e pilot arc is ignited When the pilot arc touches the workpiece the cutting arc arises If the cutting arc does not arise the pilot arc automatically switches off after ca 2 seconds Warning Don t repea...

Page 12: ...hold the manual cutting torch sloped and then change into vertical position in order to reduce spatter formation on the plasma nozzle 8 Service and Maintenance This cutting unit should be serviced in...

Page 13: ...unctions The LED D2 5V indicates the correct voltage on the PCB The LED D3 OK shows the normal function of the microprocessor The LED D4 BT shows the function of the torch trigger and the possible err...

Page 14: ...ight Torch trigger is pressed Error functions 1x flash The cutting transformer has turned off no cutting current 2x flash The reed contact has turned off no cutting current 3x flash Reed contact is fa...

Page 15: ...p insufficient pressure remove shortage of comes on when torch air supply compressed air trigger is pushed overheating of the unit is ready for work machine again after ca 5 minutes if fan is running...

Page 16: ...Plasma 33 H Operating Manual Page 12 12 Spare Parts Picture 12 1 Sideview...

Page 17: ...g in socket green 712 024 002 Bulb 24 V 463 024 012 17 Main switch M225 645235 440 220 033 Grip for main switch 440 225 051 18 Housing bonnet 715 021 007 Case handle 305 179 005 19 2 channel blade ter...

Page 18: ...742 0011 12 2 Insulating sleeve for HF version 742 0038 17 Cap 742 0004 18 Spring 742 0089 21 Safety clamp cpl 742 0099 30 Handle with single action switch 742 0044 consisting of Handle left and right...

Page 19: ...3 14 workpiece torch 06 02 04 K1 14 H1 H2 Mains lamp Malfunction lamp A1 A2 A3 C1 Ignition unit SIG 3 6 HF terminating PCB P1 H Capacitor 2 2 F 250V F1 F2 Fuse PCB PL 3 S1 Torch trigger Thermal switch...