Plasma 25ci
Operating manual
Page 14
15. Technical data
Supply voltage 1-phase
230 V, 50 Hz, +/- 10%
Max. power draw
5,6 kVA
Fuse
16 A slow
Cutting current
7 to 25 A
Max. open-circuit voltage
460 V
35 % duty cycle
25 A / 90 V
60 % duty cycle
20 A / 88 V
100 % duty cycle
15 A / 86 V
Max. cutting thickness, quality cut
4 mm
severance cut
6 mm
System of protection
IP 23 / IP44
Insulation class
F (180° C)
Type of cooling
F
Dimensions L x W x H (mm)
425x210x390 (IP23)
590x220x410 (IP44)
Weight
17kg (IP23) / 19kg (IP44)
Compressor:
Supply voltage 1-phase
230 V, 50 Hz
Max. power draw
450 W
Max. pressure
8 bar
Max. Airflow
45l/min at 5 bar
Noise
70 db
Authorized for welding under increased electrical hazard
Manufactured in accordance with EN 60 974-1 and EN 60 974-10
Generator operation:
The generator must have 30% more power as the cutting unit.
Example: 6kVA (unit) + 30% = 8kVA. The generator for this unit must have 8kVA.
A generator with less power will damage the Jäckle cutting unit as well as the generator himself
and is disallowed.
16. Environmental conditions
The power source must be operated at a temperature between -10°C to +40°C and a relative humidity of 50% at
40°C or up to 90% at +20°C. The ambient air must be free of unusual amounts of dust, acids, corrosive gases or
substances, etc., unless they occur during cutting.