12. Technical data
dualMIG 250E
Power source
Supply voltage, 50/60 Hz
400 V, 3-phase, +/- 10%
Drawing of current
Imax = 15 A, Ieff = 11A
Fuse
16 A slow
Max. power draw
11 kVA
Set-point range
40 - 250 A
Operating voltage
16 – 26,5 V
Open-circuit voltage
21 - 42 V
Voltage steps
12
Duty cycle 20 % (40°C)
250 A / 26,5 V
Duty cycle 60 % (40°C)
170 A / 22.5 V
Duty cycle 100 % (40°C)
120 A / 20 V
System of protection
IP 23
Insulation category
H (180° C)
System of cooling
F
Weight
84 kg
Dimensions L x W x H (mm)
860 x 445 x 880
Noise emission
< 70 dB(A)
Wire feed
Wire feed motor with
42 V, 50 W
Wire feed speed
0,8 - 24 m/min
Diameter of wire
0.8 - 1.2 mm
Authorized for welding under increased electrical hazard
Manufactured in accordance with EN 60 974-1 and EN 60 974-10
Generator operation:
The generator must have 30% more power as the welding unit.
Example: 11kVA (unit) + 30% = 15kVA. The generator for this unit must have 17kVA.
A generator with less power will damage the Jäckle welding unit as well as the generator himself
and is disallowed.
13. Environmental conditions
The power source must be operated at a temperature between -10°C to +40°C and a relative humidity of 50% at
40°C or up to 90% at +20°C. The ambient air must be free of unusual amounts of dust, acids, corrosive gases or