4
/
8
3.3 Speed adjustment
Press
or
to change the speed. 50 difference once a time and can press constantly.
3.4 Factory setting
Press
for factory setting.
3.5 Method to monitors mode
Press
and
shows monitors number
,
press
or
to change the monitors number
,
press
to enters into the related value of monitors number, press
again to return the monitors reference
number.
(
if the monitor number is 24
、
25
、
26
、
28, press
shortly when shows the related value then can
back to the monitors number
,
press
to save the current monitors’ value and if shows ok, it means saved
successfully. Press
shortly and exit the monitors mode.
)
Note: how to set needle position, enters parameter 24 and adjust hand wheel to change the needle position, then
press
to check the value, then press
for a long time (needle position will change accordingly), press
to
exit monitors mode.
3.6 Parameters
3.6.1 Operators parameter
param
eters
descriptions
Factory
value
range
num
ber
descriptions
Factory
value
range
P00
Starting speed (r/min)
200
100-80
0
P23
Curve mode of the pedal
0
:
straight line
1
:
two phase slope
2
:
curve
(
square
)
3
:
S curve
0
0-3
P01
Highest speed (r/min)
3500
200-50
00
P24
Thread trimmer position of the
pedal
150
0-4095
P02
Multi-phase speed
(r/min)
3000
200-35
00
P25
Back safty stitch(sucking)
27
1-120
P03
Needle position
0
:
top
1
:
down
1
0-1
P26
Front safty stitch(releasing)
18
1-120
P04
Front bar tack sewing
speed (r/min)
1800
200-30
00
P29
Auxiliary parameters
0
:
aquare
1: cube
1
0-1
P05
Back bar tack sewing
speed(r/min)
1800
200-30
00
P30
Powerful when the motor
under low speed
0
:
normal
1
—
31 more powerful
0
0-31
P06
W sewing speed(r/min)
1800
200-30
00
P31
Thread trimmer strength
40
10-60
P07
Slow starting sewing
speed(r/min)
800
100-80
0
P32
Tread tension magnet
time(from beginning to full
energy)
40
1-200