background image

3

/

8

2.2The description of each key function

number

picture

diagram

Function description

1

Enter the parameter

area function key

Parameter function entry key

2

Parameter view save

key

View and save the selected parameter number

3

Speed plus

Initial standby speed plus

4

Speed reduction

Initial standby speed reduction

5

Left key

1

adding

2

adding

6

Right shift key

1

reducing

2

reducing

7

Display cutover key

Toggles the window display and needle setting

for the ABCD segment or EFGH segment

8

Front safety switch

Reinforcement sewing part(A-B)

one time or two times Before switching

9

Back safety switch

Reinforcement sewing part(C-D)

one time or two times Before switching

10

W stitch / multi-section

stitch

Short press to select W

sewing mode /

long press to select multi-segment sewing mode

11

Restore factory settings

key

Press and hold 3S to restore the factory settings

12

Free stitch/ cut thread

Short press to select free stitch mode /

long press to turn on the thread trimming

function or off it

13

Stop needle position

selection/clip thread

Switch on/off the tension post function when

pressing the top/down needle position shortly

3

Parameters adjustments

3.1 Method to enter into operators parameters and saving

Press

for a long time and then press

shortly then enters into parameters

Press

or

to

modify related parameters

If not modified, press

to back

if modified successfully, press

then

shows ok and back to the main menu. Press

to exit the parameters mode.

3.2 Method to enter into technicians parameters and saving

Press

+

for a long time and power on, same method as operators parameter.

企业识别系统手册

CORP

OR

ATE IDEN

TIT

Y S

YST

EM 

GUIDELINE

S

Summary of Contents for ZB-A2S

Page 1: ...nnected to an effective way to earth All parts for the repair provided by the Company or approved before use performing any maintenance action you must turn off the power and unplug the power cord There are dangerous high voltage control box you must turn the power off after one minute before opening the control box This manual marked with the symbol of the Department of Safety Precautions must be...

Page 2: ...or grounding and please make sure it is grounded before operating thus can prevent abnormal conditions Note please don t twist or press while grounding power wire signal wire grounding wire etc for making sure safety 2 Operation panel instructions 2 1Operation panel display instructions According to the system working state The Digital pipe of the operation panel will display the current sewing st...

Page 3: ...press to select W sewing mode long press to select multi segment sewing mode 11 Restore factory settings key Press and hold 3S to restore the factory settings 12 Free stitch cut thread Short press to select free stitch mode long press to turn on the thread trimming function or off it 13 Stop needle position selection clip thread Switch on off the tension post function when pressing the top down ne...

Page 4: ...y press to exit monitors mode 3 6 Parameters 3 6 1 Operators parameter param eters descriptions Factory value range num ber descriptions Factory value range P00 Starting speed r min 200 100 80 0 P23 Curve mode of the pedal 0 straight line 1 two phase slope 2 curve square 3 S curve 0 0 3 P01 Highest speed r min 3500 200 50 00 P24 Thread trimmer position of the pedal 150 0 4095 P02 Multi phase speed...

Page 5: ...tarting sewing stitches 1 1 9 P33 Tread tension magnet period from beginning to full energy 6 1 10 P09 Slow starting sewing switch 0 off 1 on 1 0 1 P34 Multi phase mode 0 off 1 on 0 0 1 P10 W sewing stitch sucking 27 1 120 P35 Thread tension switch 1 0 1 P11 W sewing stich releasing 18 1 120 P36 Angle of finishing testing the top thread 25 1 360 P12 Half stitch delaying time ms 150 1 180 P37 Closi...

Page 6: ...omatic testing mode 0 0 3 P86 Transition point speed between two phase slope r min 1500 0 4000 P63 Aging stopping time s 2 1 255 P87 Analog quantity between two phase slope 2700 0 4095 P64 Retain 0 0 1 P88 Piece number unit 1 1 50 P65 Factory setting 0 no operation 1 factory value 2 technicians value 0 0 2 P89 Piece number calculation 9999 1 9999 P66 Machine head safety switch test 1 0 1 P90 Piece...

Page 7: ...observe whether the normal work Retry several times if the fault occurs frequently replace the controller and inform the manufacturer Err 08 Motor stalled Disconnect the power of the controller check whether the motor power input plug is off loose broken whether there is foreign body wrapped around the machine head After resetting the system still does not work replace the controller and inform th...

Page 8: ...ine when the finished the cutting action 3 Make sure the parameter value should be arranged as below parameter No 24 parameter No 70 parameter 75 parameter 75 72 parameter 75 73 parameter 74 4 It can be monitored by the mode of 025 026 028 parameters in real time to monitor the pedal analog maximum pedal back to the voltage sampling value pedal trimming voltage sampling value the operation mode wi...