CONFIDENTIAL
PROJECT NAME
| date
项目名称
|
日期
28
Troubleshooting-
Fault table
E 731
Communication Error between main
shaft and stepper
Communication conflict
Turn off the power. Check if the encoder signal is normal
E 733
Main shaft over-current
Motor stop
If there is no machine problem, then check the connection of
the main shaft encoder
E 811
Over-voltage Error
The voltage of power is over the specified value
Confirm the voltage of power
E 813
Low Voltage Error
The voltage of power is too low
Comfirm the voltage of power
E 901
Main shaft driver abnormal
The error is detected in main shaft driver
Turn off the power and repower the machine after a while
E 903
Stepping driver Error
Over-current occurs to stepping drive board
Turn off the power and repower the machine after a while
E 904
24V power supply error
24V over-current
Turn off the power and repower the machine after a while
E 906
Main shaft out of control
Main shaft motor is out of control
Turn off the power and repower the machine after a while
E 907
X origin detection abnormal
X origin sensor does not change
Turn off the power switch, confirm if the head signal circuit
board CZ021, control box X9 are loose or off.
E 908
Y origin detection abnormal
Y origin sensor does not change
Turn off the power switch, confirm if the head signal circuit
board CZ022, control box X9 are loose or off.
E 910
Presser original detection abnormal
Presser origin sensor doesn't change
Turn off the power switch, confirm if the head signal circuit
board CZ025, control box X9 are loose or off.
E 913
Thread-catching origin search Error
Thread-catching origin sensor doesn't change
Turn off the power switch, confirm if the head signal circuit
board CZ026, control box X9 are loose or off.
E 914
Feeding abnormal
Feeding and main shaft are not synchronized
Turn off the power and repower the machine after a while.
Feeding angle is wrong
E 915
Communication Error between main
board and operator panel
Communication between main board and operator
panel is down
Turn off the power and repower the machine after a
while.Check the connections of the communication cable,
main board and operator panel
E 916
Communication Error between main
board and stepping board
Communication between main board and stepping
board is down
Turn off the power and repower the machine after a
while.Check the connections of the communication cable,
main board and drive board
E 943
Main circuit board EEPROM read
and write Eror
Main circuit board can not read and write
EEPROM
Turn off the power and repower the machine after a
while.Check if the 26, 27 feets of X9 plug are cut off
。
Summary of Contents for JK-1900BSK
Page 1: ...CONFIDENTIAL PROJECT NAME date 1 1900BSK LED PANAL of DAHAO...
Page 14: ...CONFIDENTIAL PROJECT NAME date 14 Operation Instructions Patterns for bar tacking...
Page 15: ...CONFIDENTIAL PROJECT NAME date 15 Operation instruction List of bartack patterns...
Page 16: ...CONFIDENTIAL PROJECT NAME date 16 Operation instruction List of buttonattaching patterns...
Page 17: ...CONFIDENTIAL PROJECT NAME date 17 Operation instruction List of buttonattaching patterns...